Re
vi
si
o
n 1
.0
Product Manual
ITSCAM FF 600
12
www.pumatronix.com
•
Dimensions:
Front View
Side View
A) Height
B) Width
C) Length
Dimensions in millimeters
245*
140
511
Electrical Specifications
•
Power: 90 VAC~264 VAC (mandatory grounding at installation site)
•
Maximum input current: 1.5 A
•
Typical power: 24 W in maximum steady state
•
Maximum power: 63 W only at equipment start-up
•
Reverse polarity protection: 45 V with a fast response of 2 µs to reverse polarity (ISO 7637-2);
•
Overvoltage protection (max.): 36.7 V in 10/1000 μs (IEC 61000
-4-5:2014);
•
Protection against electrostatic discharge (DC supply): ±30 kV by contact - Level B (IEC 61000-4-
2/AEC Q100-002) and ±30 kV by air (IEC 61000-4-2/AEC Q100-002);
•
Fast electrical trans
ient (EFT) protection (DC supply): direct current peak at 10/1000 μs up to 53.3
A ±5% (ISO 7637 and IEC 61000-4-4);
•
Inrush current protection: 8 A in 2 seconds (IEC 63129:2020).
Connection Board
Interface
Electrical Specifications
4 digital inputs/outputs
(IOs)
with bidirectional 3.75 kV insulation programmed by the user (maximum current 50 mA,
maximum voltage 28 Vdc and impedance of 10 kΩ)
RS-485/422 Serial Port Half Duplex port with electrostatic discharge protection of ±8 kV by contact (IEC 61000-
4-2) and ±15 kV by air (IEC 61000-4-2)
RS-232 EIA/TIA Serial
Port
Port with a maximum transmission rate of 115,200 kbps and protection against
electrostatic discharge of ±8 kV by contact (IEC 61000-4-2) and ±15 kV by air (IEC
61000-4-2)