background image

CR-2010 BBR

Model No.: 27xx...

Circular Chart Recorder

Pro

G-Tek Corporation Pvt. Ltd.

3, mahavir estate, karelibaug
vadodara-390 018
tel.: +91-265-2461912
email: [email protected]
url: www.gtek-india.com

OPERATING

MANUAL

      

 CR-2010 BBR

Pro

Summary of Contents for 27 Series

Page 1: ...odel No 27xx Circular Chart Recorder Pro G Tek Corporation Pvt Ltd 3 mahavir estate karelibaug vadodara 390 018 tel 91 265 2461912 email info gtek india com url www gtek india com OPERATING MANUAL CR...

Page 2: ...ING AND INSPECTION OF RECORDER 8 6 1 INSTALLATION 10 6 2 OVERALL MECHANICAL DIMENSIONS 11 ELECTRICAL INSTALLATION 13 7 1 WIRING DIAGRAM FOR RECORDER 13 7 2 FITTING THE CHART 15 OPERATION 16 8 1 FRONT...

Page 3: ...iew of Recorder 8 Figure 2 Back view of Recorder 9 Figure 3 Environmental Conditions 10 Figure 4 Overall Mechanical Dimensions 11 Figure 5 Panel Mounting 12 Figure 6 Back panel view with notation 13 F...

Page 4: ...M Month YY Year HR Hour MN Minute SAV Save NBT No Battery BAT ON Battery BAL Battery Low OFS Offset Menu MC Mechanical Calibration Menu PEZ Pen zero scale position PEF Pen full scale position CAL Cali...

Page 5: ...e parameter specified in the technical data Using it beyond the specified limit can cause the damage to the product and personnel also Do not use the product if there are signs of damage to the housin...

Page 6: ...r comes with built in battery backup to ensure the proper working in case of power failure The recorder comes with single channel single pen for continuous marking of temperature data and 3 digit LCD...

Page 7: ...programming and calibration Analog Input RTD PT 100 Sensor Type and Range Refer to Table 1 Scan Rate Continuous 1 reading per second Memory Memory Size 64KB Data Storage Up to 14 days at 5min Store I...

Page 8: ...Non Condensing Storage 5 to 90 RH Non Condensing Altitude 2000 meter Power Requirement Supply Voltage Mains Operated 85 264 V AC 47 63Hz Battery backup Yes DC Adapter Operated Yes Power 15 W Max with...

Page 9: ...100 7 Day 6 307001 W60100 29 50 to 50 7 Day 6 307010 W6 50 50 30 50 to 50 7 Day 6 307009 W650 50 31 100 to 50 7 Day 6 307005 W6 100 50 32 50 to 100 7 Day 6 307008 W650 100 33 40 to 10 7 Day 6 307007...

Page 10: ...from the box Open the door of the recorder by rotating the knob Figure 1 Open the chart plate by opening the captive screw and inspect the recorder for mechanical integrity Close the chart plate and...

Page 11: ...Page No 9 Figure 2 Back view of Recorder RTD connection 12VDC battery connection Door switch connection LNE mains connection...

Page 12: ...onditions for better operation The environmental conditions are shown in Figure 3 Attention Select a location away from strong electrical and magnetic field If this is not possible particularly in app...

Page 13: ...MECHANICAL DIMENSIONS Figure 4 Overall Mechanical Dimensions Table 3 Overall Mechanical Dimensions Overall Dimensions approx Dimensions L x W x D mm 232 x 205 x 117 Panel Cutout L X W mm 198 x 169 Be...

Page 14: ...Page No 12 The panel mounting of recorder is shown in figure 5 Figure 5 Panel Mounting...

Page 15: ...NG DIAGRAM FOR RECORDER Refer the figure 6 to connect AC mains 12V DC Input door switch input and sensor to the recorder Figure 6 Back panel view with notation RTD connection 12VDC battery connection...

Page 16: ...ground is essential Such connection not only reduces the possibility of electric shock but also provides the required return for the recorder line power filters All local electrical codes of practice...

Page 17: ...llow the steps 1 Open the door of the recorder 2 Park the pen on full scale position 3 Unscrew the chart knob as shown in figure 7 4 Remove the chart 5 Insert the new chart 6 Screw the knob after sett...

Page 18: ...ps there The full range of the chart arrived as under Full range 100 of the chart value Range low of the chart Span of the chart e g for the chart with the marking of 50 to 100 with 50 marked at the c...

Page 19: ...ce you enter in the Sr menu you must set the RTC otherwise the default value will be set for DD MM YY HR MN If no activity is observed on keyboard after 2 minutes the display will automatically turn o...

Page 20: ...splay shows battery status on the display for 3 seconds and then come back to its normal condition Display shows only one status from these three refer figure 10 as per the connection on the device Al...

Page 21: ...Display in normal condition is off D17 Display for 3sec M10 Y19 Display for 3sec Display for 3sec M17 Display for 3sec H12 Display for 3sec nbt Display for 3sec OR bat nbt Mains and battery both are c...

Page 22: ...reading by the sequence shown in figure 12 The time out for Offset menu of display is 2 minutes after that the display will be off An offset can be given in the range of 99 9 to 99 9 OR Note In betwe...

Page 23: ...lay will be off On Power up Press Up and Down Key simultaneously to access the Mechanical Calibration Menu Figure 13 Mechanical calibration On Power Up Press Up and Down key simultaneously By using UP...

Page 24: ...may need to carry out same exercise twice or thrice to set the value properly cal Status is blinking during the calibration process on display Keys Pen is moved away from the center of the chart Pen...

Page 25: ...f the input is within the range carryout the mechanical calibration If problem persists contact factory Pen movement is jerky Contact factory Pen is positioned properly but it is not marking In case o...

Page 26: ...Page No 24 STANDARD ACCESSORIES Charts Pack of 30 Panel Mounting Clamps 2 numbers Figure 14 Accessories Standard Accessories Optional Accessories...

Page 27: ...nsor Type CR PD PS RE PI x x R CS S 1 CR4 NU 0 1P ND 0 85 264 V CE 0 None 0 None 0 PG 0 P G 0 Uni 2 CR6 NU 1 1P D 1 12 15V DC 1 1 1 RS 232 1 Fixed Specify 1 4H 1 RTD 3 CR11 NU 2 2P D 4 85 264V CE BB 2...

Reviews: