Page 2: ...under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be give...

Page 3: ...cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European market in some...

Page 4: ...beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit cl...

Page 5: ...llation 9 7 5 Soil temperature installation 9 8 Operation 10 8 1 Sensor schematic 10 8 2 Measurement and output linearization 10 8 3 Electrically noisy environments 11 8 4 Long cable lengths 11 9 Trou...

Page 6: ...urning when tested according to U L 94 H B and passes FMVSS302 However local fire codes may preclude its use inside buildings 3 Initial inspection Check the packaging and contents of the shipment If d...

Page 7: ...ng procedure also describes programming with Short Cut 1 Open Short Cut and click Create New Program 2 Double click the data logger model 3 In the Available Sensors and Devices box type 107 or find th...

Page 8: ...e wired to the data logger Click OK after wiring the sensor 5 Repeat steps three and four for other sensors being measured Click Next 6 In Output Setup type the scan rate Data Output Storage Intervals...

Page 9: ...he 107 is a rugged probe that accurately measures air soil or water temperature in a variety of applications The sensor consists of a thermistor encapsulated in an epoxy filled aluminium housing This...

Page 10: ...error 0 01 C 35 to 50 C Probe weight and dimensions Weight with 10 ft cable Length Diameter Compliance 136 g 5 oz 10 4 cm 4 1 in 0 762 cm 0 3 in View the EU Declaration of Conformity at www campbellsc...

Page 11: ...t instruction 7 2 Data logger programming Short Cut is the best source for up to date data logger programming code If your data acquisition requirements are simple you can probably create and maintain...

Page 12: ...ons l Temperature reported as C set Mult to 1 and Offset to 0 l Temperature reported as F set Mult to 1 8 and Offset to 32 l AC mains noise filtering set Integ fN1 to the 60 Hz or 50 Hz option see Ele...

Page 13: ...ion the RAD06 shield has lower self heating in bright sunlight combined with higher temperatures 24 C 75 F and low wind speeds 2 m s 4 5 mph giving a better measurement The 41303 5A and RAD06 attach t...

Page 14: ...ld in place Route the sensor cable to the instrument enclosure Secure the cable to the tripod or tower using cable ties 7 4 Water temperature installation 107 probes can be submerged to 15 m 50 ft or...

Page 15: ...vious FIGURE 8 1 p 10 Therm107 applies 2000 mV excitation at the Vx line and measures the voltage drop across the 1 k resistor at the Vs line The ratio of measured voltage Vs to excitation voltage Vx...

Page 16: ...07_C 1 U1 U10 0 60 1 0 0 0 CR800 series and CR3000 data loggers example Therm107 T107_C 1 1 Vx1 0 _60Hz 1 0 0 0 8 4 Long cable lengths Long cable lengths 50 ft may require longer than normal analogue...

Page 17: ...le for signs of damage and possible moisture intrusion Symptom Unstable temperature is reported Probably a result of electromagnetic interference Try using the 50 Hz or 60 Hz options for the fN1 param...

Page 18: ...nterchangeability offset described in Specifications p 5 10 Attributions and references Santoprene is a registered trademark of Exxon Mobile Corporation Measurement Specialties is a trademarked global...

Page 19: ...ited for additional refinement NOTE Once the file is edited with CRBasic Editor Short Cut can no longer be used to edit the program it created 2 To add the Short Cut wiring information into the new CR...

Page 20: ...Wire Data logger Colour Function Terminal Black Voltage excitation input VX1 EX1 Red Analogue voltage output SE1 Purple Bridge resistor ground Ground Symbol Clear Shield Ground Symbol Declare the vari...

Page 21: ...utput C 40 4071186 40 00 39 3798837 39 00 38 3546330 38 00 37 3312107 37 00 36 3094743 36 00 35 2892930 35 00 34 2705469 34 00 33 2531260 33 00 32 2369292 32 00 31 2218639 31 00 30 2078448 30 00 29 19...

Page 22: ...285 18 00 17 923112 17 00 16 869600 16 00 15 819493 15 00 14 772557 14 00 13 728575 13 00 12 687344 12 00 11 648680 11 00 10 612407 10 00 9 578366 9 00 8 546408 8 00 7 516394 7 00 6 488196 6 00 5 4616...

Page 23: ...684 9 00 10 207801 10 00 11 197518 11 00 12 187799 12 00 13 178610 13 00 14 169921 14 00 15 161700 15 00 16 153921 16 00 17 146558 17 00 18 139586 18 00 19 132983 19 00 20 126727 20 00 21 120799 21 00...

Page 24: ...35 63491 35 00 36 60755 36 00 37 58150 37 00 38 55670 38 00 39 53309 39 00 40 51060 40 00 41 48917 41 00 42 46875 42 00 43 44929 43 00 44 43073 44 00 45 41303 45 00 46 39615 46 00 47 38005 47 00 48 3...