P111 End Point
This parameter determines the Distance at which the DATEM trace will fall to
the value of Sensitivity (P905 Xducer 1) and (P915 Xducer 2).
P112 Min DATEM
This parameter determines whether the Min DATEM is in use or not.
Options are:
0 = No (Min DATEM not in use) DATEM update will not be restricted and will
update right back to the ringdown.
1 = Yes (Min DATEM applied) DATEM update is restricted to the values entered
in P109, P110 and P111, which will ensure that DATEM is held off the
ringdown.
Default = 0.8m
Default = 1
P111 End
Point metres