PULSAR MEASUREMENT
65
PZ15 FLANGE SENSOR MOUNTING METHODS IN ROUND PIPES
Notes:
1. Use the ¾” NPT “Isolation Coupling”
supplied and hand tighten only. Do
not clamp sensor body or stem.
2. Do not mount sensor or cover flange
in direct sunlight.
3. Extend sensor cable up to 500 ft (150
m) with RG62AU coaxial only and
junction box.
4. Standpipe diameter as large as
possible, typical standpipe: 6” / 150
mm diameter, 12” – 16” (300 – 500
mm) height.
Use a Sensor Sunscreen (option PZS) when sensor is installed indirect sunlight.
Sunscreen
Min Range
P Z15 8" (203.2m m )
P Z 34 16" (406.4m m )
Level Sensor
Max Range