![Pulsar Measurement Greyline AVFM 6.1 Instruction Manual Download Page 30](http://html1.mh-extra.com/html/pulsar-measurement/greyline-avfm-6-1/greyline-avfm-6-1_instruction-manual_1625414030.webp)
AVFM 6.1 INSTRUCTION MANUAL
30
QZ02L VELOCITY-LEVEL SENSOR MOUNTING
Mount the QZ02L sensor with the stainless steel
bracket and hardware supplied. Ensure that the
sensor is parallel to the water surface (check with
a level). Mount with the tapered end of the
sensor pointing upstream and the sensor cable
pointing downstream.
Clip or tie wrap the sensor cable securely to the
pipe or channel wall.
Note: The mounting bracket is designed to
release the sensor if weeds or rags are caught by
the sensor.
FASTEN SENSOR
CABLE TO PIPE OR
CHANNEL WITH
METAL CLIPS OR
TIE WRAPS
SENSOR
END VIEW
MB-QZ
MOUNTING
BRACKET
0.2"
(5 mm)
TOP VIEW
FLOW
SIDE VIEW
FASTEN MOUNTING
BRACKET WITH A
SET SCREW
INSERT SENSOR INTO
MOUNTING BRACKET
QZ02L
VELOCITY/LEVEL SENSOR
FLOW
LEVEL
SENSOR