IMPORTANTE!.
Per apparecchi connessi permanentemente si dovrà incorporare alla cavetteria un sistema
di sconnessione facilmente accessibile.
+
~
~
-
ON
FUERZA
MEMORIA
PROG/RES
RADIO
MOTOR
220V.
CSEG
FCC
FCA
PALT
PAB
I5.PARO SUAVE.
I1.BAJADA AUTOMATICA
I2.GOLPE DE INVERSION
I3.INHIBICION PARO
AL ABRIR
I4.CIERRE POR C.SEG.
T.FUNC.
T.BAJ.AUT.
+
+
+
TEST
12v
0v
ELECTROC.
1
2
3
4
5
6
7
8
9
10
11 12
13
14
15
16
17
18
From now on any code received will be memorized, pressing the channels of the functions we wish to activate
automatically.
Confirmation of memorization is indicated by the red indicator Led.
Memorization mode will stop automatically 10 seconds after the last code input and is indicated when the red
indicator Led goes off.
B) Memorization via radio through another channel.
To use this system it is necessary to have memorized at least one code using system a).
Press the special function of one of the previously memorized channels so that we enter in the sequence of
memorization of codes. The red Led will light.
From now on, any code received with the same function as that memorized using the special function will be
recorded. To do this press the channels previously recorded with the same function by the channel used in this
system
.
To memorize any different function use system a)
Confirmation of the memorization is indicated by the red Led indicator.
10 seconds after the last reception of a code the memorization mode will terminate and the red Led indicator will go
off. Exit can be made before time pressing the special function of one of the memorized channels.
C) Memorization via radio with Easy Programming Code.
To use this system it is necessary that the memory of the receiver has the Easy Programming Code (CPF) recorded
previously. To record a CPF in the memory we need to use the Driver, recording said memory, or memorizing the
first channel with a CPF in a virgin receiver memory.
To record a channel with CPF in panel which already has CPF we only have activate the rear button and the channel
will be recorded automatically in the receiver (panel).
The recording of the CPF is temporary and will deactivate if we press the channel more than 20 times.
Cancelling of all Codes
Using “reset” we can cancel all the codes in the memory.
Press PROG/RES for 4 seconds. On releasing the button the red Led will flash indicating that all
Previously recorded codes are cancelled. New codes may now be memorized.
Indication of Memory Full Technical Characteristics
If all the available memory is full, there will be 253 different codes memorized. On trying to
Memorize new codes the red Led indicator will flash for 10 seconds.
Characteristics
Technical Characteristics
Feed
220V a.c.+10%
Motor Power
0.5 HP
Outlet Accessory Feed
12Vdc 125ma
Garage Light Contact
Free
Functioning Time
3 secs. to 60 secs.
Automatic Closing Wait
3 secs. To 120 secs.
Combinations of Codes
72,000 billion
Number of Codes
253 codes
Code Programming
Self learning
Selection of Functions
Memorize code function
Frequency
433.92 Mhz
Homologations
Conforms to ETS 300-220/ETS 300-683
Sensitivity
Better than –100 dBm
Reach
Max 60 metres
Aerial
Incorporated
Temperature
0 to 70 degrees C
Size without Box