11
Maintenance
Regular maintenance on the
ENDEAVOUR
will ensure that it continues to
function properly and will extend the life of the
ENDEAVOUR
. Perform the
following steps every 10,000 forms or once a month:
1. Disconnect the power cord from the
ENDEAVOUR
.
2. Remove both fold plates.
3. Vacuum any paper dust or toner that has accumulated on the feed
table and on the rollers.
Make sure that the power cord has been disconnected before
continuing!
4. Open the access panel in the side cover opposite the control panel.
5. Insert the 7/16” socket at the end of the breaker bar over the hex
shaped end on the #3 roller. This bar can now be used to rotate the
rollers.
6. Clean
the
stainless steel rollers
with a household cleaner such as
Oops
in order to remove any accumulated toner. As you clean, use the
breaker bar to rotate the rollers so that the entire roller surface is
cleaned.
7. Clean
the
rubber rollers
and the
feed belts
using a
rubber roll
rejuvenator
[available at your local office supply store]. Use the
breaker bar to rotate the rolls and feed belt as you clean so that all the
rubber surfaces are cleaned.
8. Return the breaker bar to the tool kit and replace the access panel.
9. Replace the fold plates.
10. Make sure that the
power switch
is in the
Off
position.
11. Connect the power cord to the
ENDEAVOUR
.