Liquidew I.S. User Manual
48
97092 Issue 5.3, September 2021
APPENDIX A
Enclosure
19” sub rack unit
Dimensions: 132 x 483 x 375mm (5 x 19 x 14.75”) (h x w x d)
(100mm (4”) minimum rear clearance depth for cables and vents)
Operating Environment
Indoor, safe area, 0...+50 °C (+32...+122 °F), < 90% RH
Premium Sampling Systems
Enclosure
304 stainless steel (EN1.4301) enclosure
Option for complete enclosure in 316 stainless steel (EN1.4401)
All fixtures stainless steel
Galvanized steel internal mounting plate
Open panel version available for indoor installation
Dimensions 800 x 600 x 300mm (31.5 x 23.6 x 11.8“) (h x w x d)
Enclosure Mounting
Stainless steel wall mounting brackets
Enclosure Ingress Protection IP66
Enclosure Temperature
Control
Heater/thermostat options for fixed set-point +20 °C (+68 °F) or
adjustable set-point range 0 to c50 °C (+32...+122 °F)
Heater Power Supply
110/120 or 220/240/255 V AC, 47/63 Hz
Power consumption 100 W max
Operating Environment
Shaded position, on or off shore, -20...+40 °C (-4...+104 °F)
(-40...+60 °C (-40...+140 °F) max transient)
Enclosure cooling option recommended for climate ambient > +45 °C
(+113 °F)
Sample Cooling Option
Recommended for process fluid temperatures > +40 °C (+104 °F)
Plant water supply required ≤ +30 °C (+86 °F)
Hazardous Area Certification
Certification Codes
See Appendix D