![Psion Teklogix Ikon 7505-BT User Manual Download Page 310](http://html1.mh-extra.com/html/psion-teklogix/ikon-7505-bt/ikon-7505-bt_user-manual_1622978310.webp)
Chapter 8: Specifications
HHP 5000 Imager Performance
296
Ikôn Rugged PDA (Windows Mobile 6.1) User Manual
8.4.4.1 HHP 5000 Decode Zone
Performance Focal Point
Operating Temperature
-30° to +50°C (-34° to 122°F)
Storage Temperature
-40° to +70°C (-40° to 158°F)
Humidity
up to 95% RH, non-condensing at 122° F (50°C)
Shock
18 shocks of 3,500 G for 0.5 msec at 23°C (73° F)
SR 7
inches (17.8 cm) from lens plate
SF4.5
inches (11.4 cm) from lens plate
SR Working
Range
8.3 mil
Linear
(.02 cm)
10 mil
PDF417
(.025 cm)
13 mil UPC
(.033 cm)
15 mil Data
Matrix
(.038 cm)
15 mil QR
(.038 cm)
35 mil Maxi-
code
(.089 cm)
Near
3.5 in.
(8.9 cm)
3.1 in.
(7.9 cm)
2.1 in.
(5.3cm)
2.3 in.
(5.8 cm)
2.1 in.
(7.9 cm)
2.0 in.
(5.1 cm)
Far
7.6 in.
(19.3cm)
9 in.
(22.9 cm)
13.2 in.
(33.5 cm)
10.2 in.
(25.9 cm)
8.8 in.
(22.4 cm)
13.0 in.
(33 cm)
SF Working
Range
6.6 mil
PDF417
(.017 cm)
7.5 mil
Linear
(.019 cm)
8.3 mil Data
Matrix
(.021 cm)
8.3 mil QR
(.021 cm)
10 mil
Linear
(.025 cm)
13 mil UPC
(.033 cm)
Near
2.8 in.
(7.1cm)
2.5 in.
(6.4cm)
3.4 in.
(8.6cm)
3.4 in.
(8.6cm)
2.2 in.
(5.6cm)
2.0 in.
(5.1cm)
Far
6 in.
(15.2cm)
6.5 in.
(16.5cm)
5.7 in.
(14.5cm)
5.4 in.
(13.7cm)
7.6 in.
(19.3cm)
8.9 in.
(22.6cm)