Instruction Manual for Series Cleo.2
4.1 Protection of the motor
All the single-phase versions incorporate a motor protector and they do not need additional
protection.
Note:
If the motor becomes overloaded, this will turn disconnected automatically itself. When
the temperature of the motor descends to a normal energy level, this comes back to connect
itself automatically.
MONOFÁSICO
Note:
Never put into operation the pump until it has been purged and primed.
The pump is correctly primed when the water is just below the transparent cover.
An arrow in the body of the pump indicate the correct direction of rotation.
In order to create the maximum aspiration capacity during the beginning, please close the
spill valve, start the pump and open the spill valve slowly.
If the pump does not work correctly after 5 minutes, stop the pump and verify the level of the
water in the suction line and in the same pump.
5
Put into operation
Before beginning to work in the pump, be sure of that the electrical provision is dis-
connected and cannot be connected accidentally.
The basket of the pre-filter built in the pump should be check every day and if it is necessary
verifies the cleaning. Before opening the cover of pre-filter, the valves for load and unload
must be closed.
After the cleaning, prime the pump again, close the cover of the pre-filter. The pump
could start up again.
Note:
The cleaning with high pressure is not allowed.
6
Cleaning of the basket of the pre-filter and their maintenance
Línea