GB
If the pump is not going to be used during the winter season, this should be drained or emp-
tied to avoid damages produced by the ice. In order to drain the pump, remove the backflow
valves from wastepipe (69) from the body of the pump. Not to place the screw until to use
the pump again
7
Protection against the ice
Under normal conditions of work, the pump does not need any specific maintenance.
8
Maintenance
9
Table of location of failures
Failures
Causes
1) The pump has not been filled with water.
2) The pump has not been purged.
3) Filtrations in the pipe/hose of the pump.
4) The height of aspiration is very high.
- Maximun allowed is 3 m.
5) The total lost of the load of the installation sur-
passes the capacity of the pump.
- A new calculation is required.
6) Filtrations in the shaft seal.
1) The level of the water of the Spa or Pool is too
low.
- Increase the level of the water till the half of
the pool.
2) The pipe/hose of aspiration is semi-blocked by
impurities.
- Clean the pipe/hose of aspiration.
The Pump works But do not remove water.
The pump does not work satisfactorly.
Elimination of old household-electric:
On the basis of European standard 2002/96/CE for electrical and elec-
tronic household-electric (RAEE); the old ones cannot be thrown in mu-
nicipal containers, must be gathered selectively to optimize their recycled
recovery of components and materials in order to reduce the environ-
mental impact and health impact.
The symbol of the erased container was marked on all products to re-
member the obligation to separate products for the selective collection.
The consumer must contact with a local authority or the same salesman
to inquire in relation to the correct elimination of his electrical apparatus.
10
Recycling
Manual Cleo.2_PSH 31/05/11 17:07 Página 13
Summary of Contents for CLEO.2 Series
Page 44: ...Cleo 2 Manual Cleo 2_PSH 31 05 11 17 07 Página 44 ...
Page 45: ...Manual Cleo 2_PSH 31 05 11 17 07 Página 45 ...