22
CLEARANCES
A
24’’ (610 mm) recommended for
maintenance
B
24’’ (610 mm) – Note 1
C
48’’ (1219 mm)
Note 1:
24’’ (610 mm) recommended for maintenance on the option’s side (combo units).
FLOOR PROTECTOR*
CANADA USA
D
18’’ (457 mm)
From door opening
16’’ (406 mm)
From door opening
E
N/A (USA only)
8’’ (203 mm)
F
8’’ (203 mm)
N/A (Canada only)
G
8’’ (203 mm)
N/A (Canada only)
I
N/A (USA only)
Note 2
J
8’’ (203 mm)
N/A (Canada only)
*Steel with a minimum thickness of 0.015’’ (0.38 mm) or ceramic tiles sealed together with grout.
No protection is required if unit is installed on a non-combustible floor (ex: concrete).
Note 2 :
Only required under the horizontal section of the connector. Must exceed each side of
the connector by at least 2 inches (51 mm).