17
EDDYSENSOR Operating Manual
FI1031BA Back Module
The back module of this unit
FI 1031BAfff
(where fff is the test frequency)
provides a coil connection and outputs for the analogue defect signal and
for the digital defect level. This unit is supplied in a number of frequency
versions:
5 - 10 - 20 - 50 - 100 - 250 kHz.
Output for the defect signal
to a recorder, bar graph or
oscilloscope
Output for the digital
defect signal, input for
end signal supression
in offline applications
I/O socket for the coil
Connection of display device
To connect peripheral devices such as a recorder, bar graph or oscilloscope
on which the signal is graphically displayed, use the socket Analog Signal
0 - 10V (R
O
= 100
Ohm).
2
3
4
5
1
6
Digital I/O
BNC socket for
output signal
Analog signal
0-10 V
Front
EDDYSENSOR from above
Back
FI1031BAfff
The pins are allocated as follows:
Pin
Use
1
Test signal suppr pole (5 – 30V)
2
Digital ground
3
pole (60V, 100mA), switching duration = min. 200 ms
4
Test signal suppression – pole (5 – 30V)
5
Defect – pole (60V, 100mA)
6
(+24V possible as supply for an external unit, if this is
necessary, Imax = 100mA)
6-pole socket for defect output and
end signal suppression