15
3.2 Area of application
The DLU is a fully integrated can line sensor for industrial use, for the detection of can motion and can
jam.
The DLU can detect cans in the diameter 53
– 86 mm, at a distance of max 5 mm.
4 Technical Data
4.1 Equipment Data
For details of the DLU 001.28 GZ S4 can line sensor please refer to the equipment label or to the
relevant datasheet.
4.2 Connection
A 4-pole plug is available on the DLU in accordance with M12 industrial standard. This connection
provides for optimal shielding and a high IP rating. In plugged condition, connector meets protection
level IP 67.
Suitable female connectors with cable in different lengths are available. Please ask the manufacturer.
4-pole plug S4 (M12 x 1) with supply voltage / switching outputs
Connection diagram, 4 pole connector to the controller
All DLU outputs are always protected against short circuit.
Note
: The connection cable is provided with flying
leads. It is the user’s responsibility to take
adequate measures to prevent a short circuit.
Technical Specifications:
Input voltage range VDD:
10
V DC … 30 V DC
Continuous current
400 mA
Operating temperature 0
°C … + 50 °C
Store temperature
-25
°C … +70 °C
Function
Colour
Pin
Supply voltage VDD
brown
1
Supply voltage ground GND
blue
3
Switching output n.o.
black
4
Switching output n.c.
white
2