Fibre to SAS/SATA RAID Subsystem
User Manual
127
3.
Additional Information
a.
When a disk has failed in Enclosure#1 Slot#1 and you try to power off
Enclosure#1 Slot#1 using the command “
PowerOffDisk Enclosure#1
Slot#1
”, and then remove the Disk from the slot and insert a new Disk,
the Disk will not power on because the Disk Slot is still in power off
state.
You need to use the command “
PowerOnDisk Enclosure#1 Slot#1
” to
power on the Disk Slot.
NOTE: Sometimes the “PowerOffDisk” and “PowerOnDisk”
command will need to wait for several seconds before command
execution is completed (web GUI is updated), specially when the
Raid subsystem is active or busy.
b.
When a disk has
failed in Enclosure#1 Slot#1 and you try to power off Enclosure#1
Slot#1 using the command “
PowerOffDisk Enclosure#1 Slot#1
”,
remove the failed disk, and then power-cycle the Raid subsystem, the
Disk Slot will be powered on. If you insert a new Disk in Enclosure#1
Slot#1, the Disk will be detected. Take note that using “Restart
Controller” function, instead of power-cycle, still will not power on
the Disk Slot.
NOTE: Sometimes the “PowerOffDisk” command will need to wait
for several seconds before command execution is completed (web
GUI is updated), specially when the Raid subsystem is active or
busy.
Summary of Contents for EP-3163S-F8S6
Page 1: ...Fibre to SAS SATA RAID Subsystem User Manual Revision 1 1 ...
Page 42: ...Fibre to SAS SATA RAID Subsystem 42 User Manual ...
Page 43: ...Fibre to SAS SATA RAID Subsystem User Manual 43 ...
Page 44: ...Fibre to SAS SATA RAID Subsystem 44 User Manual ...
Page 45: ...Fibre to SAS SATA RAID Subsystem User Manual 45 ...
Page 46: ...Fibre to SAS SATA RAID Subsystem 46 User Manual ...