Fibre to SAS/SATA RAID Subsystem
80
User Manual
SATA NCQ Support:
NCQ is a command protocol in Serial ATA that can only be implemented on native Serial
ATA hard drives. It allows multiple commands to be outstanding within a drive at the
same time. Drives that support NCQ have an internal queue where outstanding
commands can be dynamically rescheduled or re-ordered, along with the necessary
tracking mechanisms for outstanding and completed portions of the workload.
Disabled or Enable the SATA NCQ function.
HDD Read Ahead Cache:
This option allows the users to disable the cache of the HDDs on the RAID
subsystem. In some HDD models, disabling the cache in the HDD is necessary to
prove the RAID subsystem functions correctly.
Volume Data Read Ahead:
This option allows the users to set the Volume Data Read Ahead function. Options
are: Normal, Aggressive, Conservative, and Disabled.
HDD Queue Depth:
The queue depth is the number of I/O operations that can be run in parallel on a disk
drive. HDD Queue Depth options are 1, 2, 4, 8, 16, and 32.
Disk Write Cache Mode:
The RAID subsystem supports Disk Write Cache Mode options: Auto, Enabled, and Disabled.
If the RAID subsystem has BBM (battery backup module), selecting the Auto option will
automatically enable Disk Write Cache. On the other hand, if there is no BBM, the Auto
option will disable Disk Write Cache.
Disk Capacity Truncation Mode:
The RAID subsystem use drive truncation so that drives from different vendors are
more likely to be able to be used as spares for each other. Drive truncation slightly
decreases the usable capacity of a drive that is used in the subsystem. Options are:
Multiples Of 10G
: If you have several 120GB drives from different vendors,
chances are that the capacity varies slightly. For example, one drive might be
121.1 GB, and the other 120.4 GB. This drive truncation mode makes the
121.1 GB and 120.4 GB drives same capacity as 120 GB so that one could
replace the other.
Multiples Of 1G:
If you have 120 GB drives from different vendors, chances
are that the capacity varies slightly. For example, one drive might be 121.1
GB, and the other 121.4 GB. This drive truncation mode makes the 121.1 GB
and 121.4 GB drives same capacity 121 GB
so that one could replace the other.
No Truncation
: The capacity of the disk drive is not truncated.
Summary of Contents for EP-3163S-F8S6
Page 1: ...Fibre to SAS SATA RAID Subsystem User Manual Revision 1 1 ...
Page 42: ...Fibre to SAS SATA RAID Subsystem 42 User Manual ...
Page 43: ...Fibre to SAS SATA RAID Subsystem User Manual 43 ...
Page 44: ...Fibre to SAS SATA RAID Subsystem 44 User Manual ...
Page 45: ...Fibre to SAS SATA RAID Subsystem User Manual 45 ...
Page 46: ...Fibre to SAS SATA RAID Subsystem 46 User Manual ...