Fibre to SAS/SATA RAID Subsystem
118
User Manual
4.
To verify if Disk is really failed or still usable, you can try to power on the
Disk. To power on Disk in Slot#1 of Enclosure#1
, select “Rescue Raid Set”.
In the “Enter The Keyword” box, type “
PowerOnDisk
”, press space bar, and
then type “
Enclosure#1 Slot#1
”. The contents of “Enter The Keyword” box will
become “
PowerOnDisk Enclosure#1 Slot#1
”. Tick “Confirm The Operation”
and click “Submit”.
NOTE: Sometimes the “PowerOnDisk” command will need to wait
for several seconds before command execution is completed (web
GUI is updated), specially when the Raid subsystem is active or
busy.
Summary of Contents for EP-3163S-F8S6
Page 1: ...Fibre to SAS SATA RAID Subsystem User Manual Revision 1 1 ...
Page 42: ...Fibre to SAS SATA RAID Subsystem 42 User Manual ...
Page 43: ...Fibre to SAS SATA RAID Subsystem User Manual 43 ...
Page 44: ...Fibre to SAS SATA RAID Subsystem 44 User Manual ...
Page 45: ...Fibre to SAS SATA RAID Subsystem User Manual 45 ...
Page 46: ...Fibre to SAS SATA RAID Subsystem 46 User Manual ...