Fibre to SAS/SATA RAID Subsystem
124
User Manual
8.
To verify if Disk is really failed or still usable, you can try to power on the
Disk. To power on Disk in Slot#1 of Enclosure#1
, select “Rescue Raid Set”.
In the “Enter The Keyword” box, type “
PowerOnDisk
”, press space bar, and
then type “
Enclosure#1 Slot#1
”. The contents of “Enter The Keyword” box will
become “
PowerOnDisk Enclosure#1 Slot#1
”. Tick “Confirm The Operation”
and click “Submit”.
NOTE: Sometimes the “PowerOnDisk” command will need to wait
for several seconds before command execution is completed (web
GUI is updated), specially when the Raid subsystem is active or
busy.