Fibre to SAS/SATA RAID Subsystem
100
User Manual
5.6.4 Hardware Monitor
To view the RAID subsystem’s hardware information, click the
Hardware Monitor
link
from the
Information
menu. The Hardware Monitor Information screen appears.
NOTE: To disable auto refresh of GUI, tick the “Stop Auto Refresh”
option.
The Hardware Monitor Information provides information about controller, enclosure 1 such
as the temperature, fan speed, power supply status and voltage levels. All items are also
unchangeable. When the threshold values are surpassed, warning messages will be
indicated through the LCD, LED and alarm buzzer.
Item Warning
Condition
CPU Temperature
> 90 Celsius
Controller Board Temperature
> 70 Celsius
HDD Temperature
> 65 Celsius
Fan Speed
< 700 RPM
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.4V
Power 3.3V
< 3.0V or > 3.6V
DDR-II +1.8V
< 1.62V or > 1.98V
CPU +1.8V
< 1.62V or > 1.98V
CPU +1.2V
< 1.08V or > 1.32V
CPU +1.0V
< 0.9V or > 1.1V
DDR-II +0.9V
< 0.81V or > 0.99V
RTC 3.0V
< 2.7V