6.3 Trouble Zones
Each Protégé® SE Integrated System Controller can monitor up to 64 local trouble zones. Trouble
zones are used to monitor the status of the Protégé® SE Integrated System Controller and in most
cases not physically connected to an external zone. For example, trouble zone CP001:03 is used to
monitor the Protégé® SE Integrated System Controller’s backup battery voltage and warn the
Protégé® SE Integrated System Controller that the battery is disconnected or voltage is too low.
This can then be used to report a message to a monitoring station, remote computer, keypad or
siren.
The following table details the trouble zones that are configured in the
Protégé® SE Integrated
System Controller. The trouble type and group define the trouble that is generated by the trouble
zone when it is activated.
Zone Number
Description
Type
Group
CP001:01
Module Tamper
System Tamper
System
CP001:02
AC failure
Power Fault
General
CP001:03
Low Battery
Power Fault
General
CP001:04
Real Time Clock Not Set
RTC/Clock Loss
General
CP001:05
Service Report Test
*
*
CP001:06
Service Report Failure To Communicate
Reporting Failure
General
CP001:07
Phone Line Fault
Phone Line Lost
General
CP001:08
Auxiliary Failure
Power Fault
General
CP001:09
Bell 1 Cut/Tamper
Bell/PGM Fault
General
CP001:10
Bell 2 Cut/Tamper
Bell/PGM Fault
General
CP001:11
Bell 1 Cut/Tamper
Bell/PGM Fault
General
CP001:12
Bell 2 Cut/Tamper
Bell/PGM Fault
General
CP001:13
Module Communication
Module Loss
System
CP001:14
Module Network Security
Module Security
System
CP001:15
Expansion Device Missing
Hardware Fault
System
CP001:16
Communication Port 1 Fault
Hardware Fault
System
CP001:17
Communication Port 2 Fault
Hardware Fault
System
CP001:18
Ethernet Hardware Fault
Hardware Fault
System
CP001:19
Ethernet Link Lost
Hardware Fault
System
CP001:20
DVAC Line Fault/Polling Error
Hardware Fault
System
CP001:21
ModBUS Communication Fault
Hardware Fault
System
CP001:22
Protégé®
System Remote Access
Hardware Fault
System
CP001:23
Installer Logged In
Hardware Fault
System
CP001:24
Service 1 Stopped
Hardware Fault
System
CP001:25
Service 2 Stopped
Hardware Fault
System
CP001:26
Service 3 Stopped
Hardware Fault
System
CP001:27
Service 4 Stopped
Hardware Fault
System
CP001:28
Reserved
*
*
| | | |
| |
|
|
CP001:64
Reserved
*
*