25
8.2 Defaulting a Controller
The Protégé® SE Integrated System Controller can be set back to factory default using the following
procedures. This will reset all internal data and event information.
Step 1
Remove power from the controller by disconnecting the AC and battery supply.
Step 2
Turn ON Configuration Dip Switch 4.
Step 3
Power up the Protégé® SE Integrated System Controller by turning on the AC supply.
Step 4
Turn OFF Configuration Dip Switch 4 once the Protégé® SE Integrated System Controller is
indicating normal status by flashing the green status indicator. The system will now be defaulted
with all programming and settings returned to factory configuration.
?
Defaulting the Protégé® SE Integrated System Controller will not reset the IP
address.
To reset an IP address refer to the section Configuration Switch on
page 24.