EN
19
System function test
1.
A1. Switch exhaust air device ON and open the
window
>
exhaust air device must switch on
2. Close the window
>
exhaust air device must switch off
3. Open the window once more
>
exhaust air device
must switch on again
Meaning of LED displays
Receiver / Central unit
LED Power (3)
Green permanent lighting
> Ready for operation
OFF
> Device fault or no power
LED-ON (4)
Green permanent light
>
Device status ON (window open)
LED-OFF (5)
Red permanent light
>
Device status OFF (window closed)
Red flashing
>
Plug guard is not plugged in or battery of window
transmitter empty
LED ON (4) and LED OFF (5)
Alternating flash
> devices in teach mode
Red and green permanent lighting
>
Transmitter has been taught in successfully
Window transmitter
OFF
> Standby mode.
Green flashing
> window opens
Red flashing
> window closes
Red 0.5 sec flashing
> Window transmitter
battery empty
MALFUNCTIONS
In isolated cases, faults may occur due to interference
by other, similar radio units. It normally suffices if you
check (and if necessary change) the location of the
components.
TECHNICAL DATA
Network voltage:
230 V ~, 50/60 Hz, approx. 1W
Switching capacity:
1800 W, 8A, at cos phi=1
Radio range:
up to 50 m
Radio frequency:
868.350 MHz
Protection class:
IP 20, only for dry rooms
Battery (window
1x 3V lithium CR2477
transmitter):
(battery life approx. 2 years)