Reference
MVI56E-FLN ♦ ControlLogix Platform
User Manual
FA Control Network Ethernet Communication Module
Page 104 of 155
ProSoft Technology, Inc.
Log Data Request (Write Block) Output Data
Offset
Description
Length
0
9250
1
1 to 247
Spare
247
Log Data Request (Read Block) Input Data
Offset
Description
Length
0
Write Block ID Requested
1
1
Spare
1
2 to 3
Socket Tx count
2
4 to 5
Socket Tx error count
2
6 to 7
Socket Rx count
2
8 to 9
Socket Rx error count
2
10 to 11
Tokens Tx
2
12 to 13
Cyclic Tx
2
14 to 15
Peer-to-peer message Tx
2
16 to 17
Broadcast message Tx
2
18 to 19
Tokens Rx
2
20 to 21
Cyclic Rx
2
22 to 23
Peer-to-peer message Rx
2
24 to 25
Broadcast message Rx
2
26 to 27
Cyclic Rx errors
2
28 to 29
Cyclic Rx address size errors
2
30 to 31
Cyclic Rx CBN errors
2
32 to 33
Cyclic Rx TBN errors
2
34 to 35
Cyclic Rx BSIZE errors
2
36 to 37
Message retrans
2
38 to 39
Message over retrans
2
40 to 41
Message Rx errors
2
42 to 43
Message Rx version sequence errors
2
44 to 45
Message sequence retrans errors
2
46 to 47
ACK errors
2
48 to 49
ACK version sequence errors
2
50 to 51
ACK sequence errors
2
52 to 53
ACK node number errors
2
54 to 55
ACK TCD errors
2
56 to 57
Token multiple errors
2
58 to 59
Token discards
2
60 to 61
Token reissued
2
62 to 63
Token holding timeouts
2
64 to 65
Token monitoring timeouts
2
66 to 67
Total service time (seconds)
2
68 to 69
Frames waiting
2
70 to 71
Number of nodes participating
2
72 to 73
Self exits
2
74 to 75
Exits by skipping
2
76 to 77
Exits of other nodes
2
78 to 79
Spare
2