9
20~100)
NOTE:
1. The tube cannot be bent, or it may influence airflow and suction.
2. Absorbed object surface should be smooth in order to be sucked.
3. Pay attention to prevention of ESD, so as not to damage the device
4. Before using vacuum pickup pen, turn off the hot air gun.
5. Do not overexert while fixing nozzle, use pliers to pull the nozzle, or screw breech block too
tight.
6. Be careful when working with high temperature.
7. Do not use this product near flammable gas, paper, or other flammable things.
8. The temperature of nozzle and hot air is very high and could injury user. Don’t touch the
heating part or blow the hot air to body
9. Use hot air to solder is feasible, but it could cause the problem of solder link or solder ball, for
which we highly recommend you to check it carefully.
10. For the new machine, it might occur smoke in a short time when it starts to work in the first time
due to heating insulation material inside the handle, and this is normal.
Trouble Shooting
Warning:
Before checking the inside of the SS-956 or replacing parts, be sure to disconnect the power plug.
Failure to do so may result in electric shock.
Defect Situation
Possible Problem
Solution
Dead, doesn’t work
Blown fuse
Change new fuse
SS-956E(110V) : 250V / 8A
SS-956B(220V) : 250V / 5A
SS-956H(220V) : 250V / 5A
Hot air gun - Air
temperature doesn’t
heat up
Display S-
E, plug doesn’t connect
properly
Reconnect the plug of hot air gun
(as Fig-22)
Calibration parameter changes
Calibrate again
Heating element is broken
Replace heating element
5SS-989NE-H(110V)
5SS-989NB-H(220V)
Hot air gun - Airflow
level abnormal
Internal pipe is obstructed or loose
which causes air leakage
Clear the internal pipe, reconnect
the pipe tightly.
Pump securing screws are not
loosened
Loosen the pump securing screw,
which on the bottom of rework
station.
Suction function
abnormal
Tube is broken or not installed properly
Change new tube or re-install tube
Suction cup is aging or not installed
properly
Change new suction cup or
re-install suction cup
Display shows
abnormal
Transportation causes inside PCB
board connect improperly
Open the case, reconnect the PCB
board
Input voltage lower than standard
request
Check with local power service
provider
Temperature unit
display abnormal
IC broken
Contact vendor for repair
Summary of Contents for SS-956
Page 12: ...11 SS 956 SS 956 LCD 480 C 896 F SS 956 SS 956 SS 956 600W SMD CPU...
Page 15: ...14 LCD 1 1 3 1 2 2 LCD 3...
Page 18: ...17 100 3 14 7 100 15 15 1 2 8 SMD QFP 1 16 PLCC 16 2 3 17 17 4...
Page 19: ...18 QFP 1 2 18 18 3 19 19 4 1 100g 20 20 2 21 3 21 4 20 100...
Page 21: ...20 6 1 23 2 5A 250V 220V 8A 250V 110V 5x20mm UL 23...
Page 22: ...21 SS 956 SS 956 LCD 480 C 896 F SS 956 SS 956 SS 956 600W SMD CPU...
Page 25: ...24 LCD 1 1 3 1 2 2 LCD 3...
Page 28: ...27 15 1 2 8 SMD QFP 1 16 PLCC 16 2 3 17 17 4 QFP 1 2 18 18...