TECHNICAL REVIEW (P-2) AFTER 200 MTH OF OPERATION
Take all actions of technical review after 10 mth plus:
OPERATION No. 17.
Oil and oil filter replacement
Before setting about oil and oil filter replacement, position the tractor on flat ground and pull the parking
brake. Start the engine so to obtain temperature of the coolant amounting to approx. 70
°
C (it is best to
change oil after work). Stop the engine, open the filler plug
2
,
and then
screw out drain plug
3
and drain oil to
previously prepared bathtub (container). Wait approx. 10
÷
15 min. so that used oil did not stay in the engine.
2
1
3
After draining the oil you must replace oil filter
4
. To do so you must take following action:
4
-
unscrew dirty filter;
-
apply few drops of oil onto the
sealing ring of the new oil filter;
-
screw in the new filter until sealing
ring touches filter body and then
tight is with hand making half turn
(do not tight to strong).
Attention! When uncrewing worn filter you must not use a hammer, engineer’s chisel, etc., because
such act may damage the filter body or engine block. You may use filters recommended by the
engine manufacturers only (original).
Attention! Screw tight the filter by hand and do not use any tools.
After havinf the filrer replaced you must screw the drain plug
3
in and fill up the engine with fresh oil through
oil filler
2
to recommended level. Twist the oil filler
2
and start the engine for couple of minutes. After
stopping the engine, wait 10 minutes and check the oil lever with use of dip rod
1
and, if need be fill it up.
OPERATION No. 18
Changing filtering element of the preliminary filter and fuel purifying element
Service life of the filter element mostly depends on degree of purity of the fuel in use. In case there is a
suspicion, that the fuel is not clean enough, you must check the filter more often and replace the filter
element. Any time you change the fuel, in connection with the autumn-winter period or winter-spring period
(however at least each 200 mth), you must change the preliminary filter element and fuel purifying element
as well.