31/18
R449A
R449A
Evap. Temp. t = -10°C / Amb. Temp. Ta = + 15°C
Evap. Temp. t = -10°C / Amb. Temp. Ta = + 5°C
Cdc
Designation
CALCUL
ecodesign
Declared
P
C
D
C
compressor
D
C
fan
Declared
D
C
Declared
COP
C
Declared
P
D
D
D
compressor
D
D
fan
Declared
D
D
Declared
COP
D
Degrad. Coeff.
(kW)
(kW)
(kW)
(kW)
(kW)
(kW)
(kW)
(kW)
Cdc
GCV R2SH4EES04 3MS/2V H N P
SEPR
29,28
7,37
0,96
8,33
3,52
32,94
6,16
0,96
7,12
4,63
0,25
GCV R2SH4EES04 3MS/2V SI H N P
SEPR
30,10
7,10
0,76
7,86
3,83
33,76
5,89
0,76
6,65
5,08
0,25
GCV R2SH4EES06 3MS/3V H N P
SEPR
30,83
6,84
1,44
8,28
3,72
34,45
5,67
1,44
7,11
4,85
0,25
GCV R2SH4EES06 3MS/3V SI H N P
SEPR
31,13
6,74
1,14
7,88
3,95
34,75
5,57
1,14
6,71
5,18
0,25
GCV R2SH4DES05 3MS/2V H N P
SEPR
33,69
8,94
0,96
9,90
3,40
38,02
7,42
0,96
8,38
4,54
0,25
GCV R2SH4DES05 3MS/2V SI H N P
SEPR
34,81
8,57
0,76
9,33
3,73
39,16
6,97
0,76
7,73
5,07
0,25
GCV R2SH4DES07 3MS/3V H N P
SEPR
35,83
8,17
1,44
9,61
3,73
40,14
6,56
1,44
8,00
5,02
0,25
GCV R2SH4DES07 3MS/3V SI H N P
SEPR
36,25
8,03
1,14
9,17
3,95
40,56
6,39
1,14
7,53
5,39
0,25
GCV R2SH4CES06 3MS/2V H N P
SEPR
40,16
11,28
1,40
12,68
3,17
45,32
9,48
1,40
10,88
4,17
0,25
GCV R2SH4VES07 3MS/2V H N P
SEPR
41,85
11,49
1,40
12,89
3,25
48,02
9,76
1,40
11,16
4,30
0,25
GCV R2SH4CES06 3MS/2V SI H N P
SEPR
41,56
10,82
0,76
11,58
3,59
46,75
8,92
0,76
9,68
4,83
0,25
GCV R2SH4VES07 3MS/2V SI H N P
SEPR
43,56
11,03
0,76
11,79
3,69
49,92
9,20
0,76
9,96
5,01
0,25
GCV R2SH4CES09 3MS/3V H N P
SEPR
43,62
10,09
3,00
13,09
3,33
48,77
8,07
3,00
11,07
4,41
0,25
GCV R2SH4CES09 3MS/3V SI H N P
SEPR
43,63
10,09
1,14
11,23
3,89
48,78
8,06
1,14
9,20
5,30
0,25
GCV R3SH4EES04 3MS/3V H N P
SEPR
44,52
10,86
1,44
12,30
3,62
50,01
9,04
1,44
10,48
4,77
0,25
GCV R3SH4EES04 3MS/3V SI H N P
SEPR
45,19
10,64
1,14
11,78
3,84
50,68
8,82
1,14
9,96
5,09
0,25
GCV R3SH4EES06 3MS/3V H N P
SEPR
45,14
10,61
3,00
13,61
3,32
50,58
8,86
3,00
11,86
4,26
0,25
GCV R2SH4VES10 3MS/3V H N P
SEPR
46,04
10,13
3,00
13,13
3,51
52,31
8,24
3,00
11,24
4,65
0,25
GCV R2SH4VES10 3MS/3V SI H N P
SEPR
46,05
10,12
1,14
11,26
4,09
52,33
8,24
1,14
9,38
5,58
0,25
GCV R3SH4EES06 4MS/4V SI H N P
SEPR
46,32
10,24
1,52
11,76
3,94
51,75
8,47
1,52
9,99
5,18
0,25
GCV R3SH4DES05 3MS/3V H N P
SEPR
51,35
13,15
1,44
14,59
3,52
57,87
10,80
1,44
12,24
4,73
0,25
GCV R3SH4DES05 3MS/3V SI H N P
SEPR
52,27
12,84
1,14
13,98
3,74
58,79
10,44
1,14
11,58
5,08
0,25
GCV R2SH4TES09 3MS/2V H N P
SEPR
53,25
13,11
1,50
14,61
3,64
60,43
10,77
1,50
12,27
4,93
0,25
GCV R2SH4TES09 3MS/3V SI H N P
SEPR
54,26
12,79
1,14
13,93
3,90
61,51
10,39
1,14
11,53
5,33
0,25
GCV R3SH4DES07 4MS/4V SI H N P
SEPR
53,85
12,22
1,52
13,74
3,92
60,32
9,80
1,52
11,32
5,33
0,25
GCV R3SH4DES07 3MS/3V H N P
SEPR
54,43
12,02
3,30
15,32
3,55
60,90
9,56
3,30
12,86
4,74
0,25
GCV R2SH4TES12 3MS/3V SI H N P
SEPR
55,49
12,25
1,65
13,90
3,99
62,87
9,86
1,65
11,51
5,46
0,25
GCV R2SH4TES12 3MS/3V H N P
SEPR
56,74
11,86
3,30
15,16
3,74
64,20
9,40
3,30
12,70
5,06
0,25
GCV R4SH4EES04 4MS/3V SI H N P
SEPR
58,24
14,84
1,14
15,98
3,64
65,54
12,43
1,14
13,57
4,83
0,25
GCV R2SH4PES12 3MS/2V H N P
SEPR
61,06
14,78
2,20
16,98
3,60
69,19
12,26
2,20
14,46
4,78
0,25
GCV R2SH4PES12 3MS/3V SI H N P
SEPR
61,06
14,78
1,14
15,92
3,84
69,19
12,26
1,14
13,40
5,16
0,25
GCV R4SH4EES04 4MS/3V H N P
SEPR
60,27
14,18
2,25
16,43
3,67
67,59
11,75
2,25
14,00
4,83
0,25
GCV R2SH4PES15 3MS/3V SI H N P
SEPR
62,77
14,36
1,65
16,01
3,92
71,54
11,79
1,65
13,44
5,32
0,25
GCV R4SH4EES06 4MS/4V SI H N P
SEPR
61,29
13,80
2,20
16,00
3,83
68,54
11,45
2,20
13,65
5,02
0,25
GCV R3SH4CES06 3MS/2V H N P
SEPR
62,41
16,21
2,20
18,41
3,39
70,20
13,36
2,20
15,56
4,51
0,25
GCV R3SH4CES06 3MS/3V SI H N P
SEPR
62,41
16,21
1,14
17,35
3,60
70,20
13,36
1,14
14,50
4,84
0,25
GCV R4SH4EES06 4MS/4V H N P
SEPR
62,30
13,48
4,40
17,88
3,48
69,53
11,13
4,40
15,53
4,48
0,25
GCV R2SH4PES15 3MS/3V H N P
SEPR
64,46
13,90
3,30
17,20
3,75
73,35
11,22
3,30
14,52
5,05
0,25
LEGENDE :
P
A
- Cooling capacity
DA - Power input
LEGENDE :
P
A
- Puissance frigorifique
DA - Puissanceabsorbée