transmitter gives sounds-, and lights signal only once, but in activated case sends constantly the ID at
regular intervals (333ms) to the HOST device until the owner transmitter is in the reading field.
Condition of monitoring
Automatic reading
Command to read
Parameter ON
At detecting a new RFID
transmitter, the device gives one
light signal and as long as the
transmitter does not leave the
reading field will be in every 250
seconds the ID to the HOST sent.
At detecting a new RFID
transmitter (it begins with the
command,) the device sends once
a light and sound signal, until the
transmitter does not leave the
reading field. With the command
of the HOST will be the last read
ID sent.
Parameter OFF
At detecting a new RFID
transmitter, the device gives one
light signal and until the
transmitter in the reading field,
sends the ID only one time.
The device detecting for new
RFID transmitter only with
command. In case of new
transmitter, gives one light- and
sound signal, send the read ID to
the HOST and then switch off the
reading field.
Adjustable sound- and light signals
On the Proxer7 device are the sound- and light signals changeable. In case of the sound signals is
there 4 versions (ON, OFF, authorized transmitter, unauthorized transmitter), all of them are adjustable
parameters. To the customization are available 12 pre-defined audio samples, each of them can be selected
as a sound signal. Light signals have two schemes. The „Proxer7” scheme is of the Procontrol Electronics
Ltd. own developed light-signaling scheme. The description of the light signaling sees at the end of the
document.
Sent bit number
The RFID transponder ID can be represented by number of bits. This parameter is a numeric value;
the Proxer7 reader will send the data according to the number of bits. The number of bits interprets by LSB.
The following table shows the effect of the parameter on the 32547698 ID. The binary is to 32 bits, the
decimal data is to 10 characters supplemented to see.
Sent bit number
Got binary and decimal numbers
32
Binary
00000001111100001010001101110010
Decimal
0032547698
20
Binary
00000000000000001010001101110010
Decimal
0000041842