background image

www.usaprocom.com

200198-01A

12

INSTALLATION

CONNECTING TO GAS SUPPLY

  CAUTION: For natural gas, 

check  your  gas  line  pressure 

before connecting heater to gas 

line. Gas line pressure must be 

no greater than 9" of w.c. If gas 

line pressure is higher, heater 

regulator damage could occur.

 CAUTION: Avoid damage to 

regulator. Hold gas regulator 

with wrench when connecting 

into gas piping and/or fittings.

  CAUTION: Use pipe joint 

sealant that is resistant to gas 

(Propane/LP or Natural Gas).

Before installing heater, make sure you have 

the items listed below:
•  external regulator for propane/LP unit only 

(supplied by installer)

•  piping (check local codes)
•  sealant (resistant to natural gas and pro-

pane/LP gas)

•  equipment shutoff valve*
•  test gauge connection*
•  sediment trap
•  tee joint 
•  pipe wrench
•  flexible gas hose (check local codes) 
* A  CSA  design-certified  equipment  shutoff 

valve with 1/8" NPT tap is an acceptable al-

ternative to test gauge connection. Purchase 

the optional CSA design certified equipment 

shutoff valve from your dealer.

Typical Inlet Pipe Diameters

Use 1/2" black iron pipe or greater. Installa-

tion must include an equipment shutoff valve, 

union, and plugged 1/8" NPT tap. Locate NPT 

tap within reach for test gauge hook up. NPT 

tap must be upstream from heater (see Figure 

10, page 13).

IMPORTANT: Install an equipment shutoff 

valve in an accessible location. The equip-

ment shutoff valve is for turning on or shutting 

off the gas to the appliance.

  WARNING: A  qualified  ser-

vice technician must connect 

heater to gas supply. Follow all 

local codes.

 WARNING: This appliance 

requires  a  3/8"  NPT  (National 

Pipe Thread) inlet connection to 

the pressure regulator.

 WARNING: For natural gas, 

Never connect heater to private 

(non-utility) gas wells. This gas 

is commonly known as wellhead 

gas.

 CAUTION: For propane/LP 

gas, never connect heater direct-

ly to the gas supply. This heater 

requires an external regulator 

(not supplied). Install the external 

regulator between the heater and 

propane/LP gas supply. Gas sup-

plier provides external regulator 

for natural gas. The installer 

provides the external regulator 

for propane/LP gas.

 WARNING: Do not over-

tighten gas connections.

 CAUTION: Use only new, 

black  iron  or  steel  pipe.  Inter-

nally tinned copper tubing may 

be used in certain areas. Check 

your local codes. Use pipe of 

1/2" diameter or greater to allow 

proper gas volume to heater. If 

pipe is too small, undue loss of 

pressure will occur.

Summary of Contents for QNSD250T

Page 1: ...ot store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical...

Page 2: ...which it is installed Provisions for ad equatecombustionandventilationairmustbeprovided Refer to Air For Combustion and Ventilation section on page 7 of this manual WARNING Improper installation adjus...

Page 3: ...nce of alcohol and those at high altitudes NATURALAND PROPANE LP GAS Natural and Propane LP gas are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the o...

Page 4: ...prevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 12 Do not use this heater as a wood burning heater Use only the logs provided with the heater 13 Solid fuels...

Page 5: ...heater can easily be changed to Natural gas by having your quali fied installer follow the instructions on page 10 and the markings on the heater LOCAL CODES Install and use heater with care Follow al...

Page 6: ...air 2 If high humidity is experienced a dehu midifier may be used to help lower the water vapor content of the air 3 Do not use an unvented room heater as the primary heat source UNPACKING 1 Remove t...

Page 7: ...appli ances WARNING This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by the method de scribed in the National Fuel Gas Code ANSI...

Page 8: ...to vinyl or cloth wall coverings or operating heater where impurities such as to baccosmoke aromaticcandles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to discolor Vent...

Page 9: ...ning wall Measure from outermost point of heater This heater is designed to sit directly on the floor or on a mantel base IMPORTANT You must maintain minimum wall and ceiling clearances during install...

Page 10: ...un m ximo de 14 W C Nunca conecte este producto directamente al tanque de suministro FOR NATURAL GAS SUPPLY PARA LA FUENTE DE GAS DEL NATURAL NOTICE An additional gas regulator will be necessary if t...

Page 11: ...the connection fitting While pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tight...

Page 12: ...n must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 10 page 13 IMPORTANT Install...

Page 13: ...from freezing rain or sleet For both gas types install sediment trap in supply line as shown in Figure 10 Place sediment trap where it is within reach for cleaning Place sediment trap where trapped m...

Page 14: ...or natural gas or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints If bubbles form there may be a leak 5 Correct all leaks at...

Page 15: ...t heater see Lighting Instructions on page 17 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 18 AAA Battery Positive UP BATTERY INSTRUCTIONS CAUTION Do...

Page 16: ...side of log 1 with one end resting on log 3 IMPORTANT Make sure logs do not cover any burner ports It is very important to install the logs exactly as instructed Do not modify logs Use only logs suppl...

Page 17: ...th the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperationof new heater burning logs will give offapaper burningsmell Orange flame will also be present Op...

Page 18: ...nds release control knob 5 Make sure the heater screen is in place before operating heater TO TURN OFF GAS TO APPLIANCE MANUAL LIGHTING PROCEDURE Note If pilot does not stay lit refer to Troubleshooti...

Page 19: ...w in structions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame Approx 3 6 A...

Page 20: ...r Inlet Holes BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500 hours of operation or every three months We also recommend that you keep the burner tube...

Page 21: ...may blow through a drinking straw if compressed air is not available CARE AND MAINTENANCE ODS PILOT CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean Exterior Use a soft cloth...

Page 22: ...nlet pressure exceeds 9 WC This is to prevent the operation of the unit on the wrong gas propane LP If your natural gas supply exceeds 9 WC the unit will not operate Either contact your gas supplier t...

Page 23: ...ntrol knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 20 or replace ODS pilot a...

Page 24: ...Care and Maintenance page 20 2 Replace gas regulator 3 Contact local gas supplier Gas odor during com bustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at top...

Page 25: ...nd Maintenance page 20 Gas odor exists even when control knob is in OFF position 1 Gas leak See Warning Statement at top of page 22 2 Control valve is defective 1 Locate and correct all leaks see Chec...

Page 26: ...www usaprocom com 200198 01A 26 PARTS MODEL QNSD250T 7 8 6 1 2 3 4 12 13 11 15 14 5 9 10...

Page 27: ...ery 1 160960 01 Metal Regulator Cap 1 REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact...

Page 28: ...g condition Warranty part s MUST be obtained through ProCom Heating Inc who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORT...