background image

www.usaprocom.com

200198-01A

4

3.  This heater needs fresh air ventilation to 

run properly. This heater has an Oxygen 

Depletion Sensing (ODS) safety shutoff 

system. The ODS shuts down the heater 

if not enough fresh air is available. See 

Air 

for Combustion and Ventilation

, pages 7. 

If heater keeps shutting off, see 

Trouble-

shooting

, page 22.

4.  Keep all air openings in front and bottom 

of heater clear and free of debris. This will 

ensure enough air for proper combustion.

5.  If heater shuts off, do not relight until you 

have provided fresh, outside air. If heater 

keeps shutting off, have it serviced.

6.  Do not run heater:

• Where flammable liquids or vapors are 

used or stored.

• Under dusty conditions.

7.  Before using furniture polish, wax, carpet 

cleaner, or similar products, turn heater 

off. If heated, the vapors from these prod-

ucts may create a white powder residue 

within burner box or on adjacent walls or 

furniture.

8.  Do not use heater if any part has been 

under water. Immediately call a qualified 

service  technician  to  inspect  the  room 

heater  and  to  replace  any  part  of  the 

control system and any gas control which 

has been under water.

9.  Turn off and unplug heater and let cool 

before servicing. Only a qualified service 

person should service and repair heater.

SAFETY

10. Operating  heater  above  elevations  of 

4,500 feet could cause pilot outage.

11. To  prevent  performance  problems,  do 

not use propane/LP fuel tank of less than 

100 lbs. capacity.

12. Do not use this heater as a wood-burning 

heater. Use only the logs provided with the 

heater.

13. Solid  fuels  should  not  be  burned  in  a 

heater  in  which  a  vent-free  log  set  is 

installed. Do not use this heater to cook 

food or burn paper or other objects.

14. To prevent sooting, follow the instructions 

in 

Care and Maintenance,

 see page 20.

15. Do not add extra logs or ornaments such 

as pine cones, vermiculite, or rock wool. 

Using these added items can cause soot-

ing. Do not add lava rock around base. 

Rock and debris could fall into the control 

area  of  heater. After  servicing,  always 

replace screen before operating heater.

16. This heater is designed to be smokeless. If 

logs ever appear to smoke, turn off heater 

and call a qualified service person.

 

Note: During initial operation, slight smok-

ing could occur due to log curing and the 

heater burning manufacturing residues.

17. Do not use this heater if any log is broken. 

Do not operate heater if a log is chipped 

(dime-size or larger).

SPECIFICATIONS

Model

QNSD250T

Gas Type

Natural Gas 

Propane Gas

Maximum Input Rating

25,000 Btu/Hr

25,000 Btu/Hr

Minimum Input Rating

13,000 Btu/Hr

21,000 Btu/Hr

Ignition Electronic Piezo Electronic Piezo

Regulator Pressure Setting

4" W.C.

9" W.C.

Inlet Gas Pressure* (inches of water) 

(*for purposes of input adjustment)

Maximum 9"

Maximum 14"

Minimum 5"

Minimum 11"

Heater Dimensions (HxWxD) • 

25" × 33.5" × 13"

Carton Dimensions (HxWxD) • 

24.8" × 34.25" × 13"

Stove Weight • 49.8 lbs

Shipping Weight • 60.4 lbs

Summary of Contents for QNSD250T

Page 1: ...ot store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical...

Page 2: ...which it is installed Provisions for ad equatecombustionandventilationairmustbeprovided Refer to Air For Combustion and Ventilation section on page 7 of this manual WARNING Improper installation adjus...

Page 3: ...nce of alcohol and those at high altitudes NATURALAND PROPANE LP GAS Natural and Propane LP gas are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the o...

Page 4: ...prevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 12 Do not use this heater as a wood burning heater Use only the logs provided with the heater 13 Solid fuels...

Page 5: ...heater can easily be changed to Natural gas by having your quali fied installer follow the instructions on page 10 and the markings on the heater LOCAL CODES Install and use heater with care Follow al...

Page 6: ...air 2 If high humidity is experienced a dehu midifier may be used to help lower the water vapor content of the air 3 Do not use an unvented room heater as the primary heat source UNPACKING 1 Remove t...

Page 7: ...appli ances WARNING This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by the method de scribed in the National Fuel Gas Code ANSI...

Page 8: ...to vinyl or cloth wall coverings or operating heater where impurities such as to baccosmoke aromaticcandles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to discolor Vent...

Page 9: ...ning wall Measure from outermost point of heater This heater is designed to sit directly on the floor or on a mantel base IMPORTANT You must maintain minimum wall and ceiling clearances during install...

Page 10: ...un m ximo de 14 W C Nunca conecte este producto directamente al tanque de suministro FOR NATURAL GAS SUPPLY PARA LA FUENTE DE GAS DEL NATURAL NOTICE An additional gas regulator will be necessary if t...

Page 11: ...the connection fitting While pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tight...

Page 12: ...n must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 10 page 13 IMPORTANT Install...

Page 13: ...from freezing rain or sleet For both gas types install sediment trap in supply line as shown in Figure 10 Place sediment trap where it is within reach for cleaning Place sediment trap where trapped m...

Page 14: ...or natural gas or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints If bubbles form there may be a leak 5 Correct all leaks at...

Page 15: ...t heater see Lighting Instructions on page 17 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 18 AAA Battery Positive UP BATTERY INSTRUCTIONS CAUTION Do...

Page 16: ...side of log 1 with one end resting on log 3 IMPORTANT Make sure logs do not cover any burner ports It is very important to install the logs exactly as instructed Do not modify logs Use only logs suppl...

Page 17: ...th the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperationof new heater burning logs will give offapaper burningsmell Orange flame will also be present Op...

Page 18: ...nds release control knob 5 Make sure the heater screen is in place before operating heater TO TURN OFF GAS TO APPLIANCE MANUAL LIGHTING PROCEDURE Note If pilot does not stay lit refer to Troubleshooti...

Page 19: ...w in structions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame Approx 3 6 A...

Page 20: ...r Inlet Holes BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500 hours of operation or every three months We also recommend that you keep the burner tube...

Page 21: ...may blow through a drinking straw if compressed air is not available CARE AND MAINTENANCE ODS PILOT CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean Exterior Use a soft cloth...

Page 22: ...nlet pressure exceeds 9 WC This is to prevent the operation of the unit on the wrong gas propane LP If your natural gas supply exceeds 9 WC the unit will not operate Either contact your gas supplier t...

Page 23: ...ntrol knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 20 or replace ODS pilot a...

Page 24: ...Care and Maintenance page 20 2 Replace gas regulator 3 Contact local gas supplier Gas odor during com bustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at top...

Page 25: ...nd Maintenance page 20 Gas odor exists even when control knob is in OFF position 1 Gas leak See Warning Statement at top of page 22 2 Control valve is defective 1 Locate and correct all leaks see Chec...

Page 26: ...www usaprocom com 200198 01A 26 PARTS MODEL QNSD250T 7 8 6 1 2 3 4 12 13 11 15 14 5 9 10...

Page 27: ...ery 1 160960 01 Metal Regulator Cap 1 REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact...

Page 28: ...g condition Warranty part s MUST be obtained through ProCom Heating Inc who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORT...

Reviews: