background image

www.usaprocom.com

5

200198-01A

QUALIFIED INSTALLING AGENCY

Only  a  qualified  agency  should  install  and 

replace gas piping, gas utilization equipment 

or accessories, and repair and equipment ser-

vicing. The term “qualified agency” means any 

individual, firm, corporation, or company that 

either in person or through a representative 

is engaged in and is responsible for:

  a) Installing, testing, or replacing gas piping 

or

  b) Connecting, installing, testing, repairing, 

or servicing equipment; that is experienced 

in such work; that is familiar with all precau-

tions required; and that has complied with 

all the requirement of the authority having 

jurisdiction.

PRODUCT FEATURES

SAFETY PILOT

This heater has a pilot with an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The 

ODS/pilot shuts off the heater if there is not 

enough fresh air.

PIEZO IGNITION SYSTEM

This  heater  is  equipped  with  an  electronic 

piezo  control  system. This  system  requires 

one AAA battery (provided).

THERMOSTATIC CONTROL

The control automatically cycles the burner 

on and off to maintain a desired room tem-

perature.

2 GAS OPTIONS AVAILABLE

Your heater is equipped to operate on either 

Propane/LP  or  Natural  gas.  The  heater  is 

shipped from the factory ready for connect-

ing to Propane/LP. The heater can easily be 

changed to Natural gas by having your quali-

fied installer follow the instructions on page 

10 and the markings on the heater.

LOCAL CODES

Install  and  use  heater  with  care.  Follow  all 

local codes. In the absence of local codes, 

use  the  latest  edition  of 

The National Fuel 

Gas Code, ANSI Z223.1/NFPA 54

*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY  10018

National Fire Protection Association, Inc.

1 Batterymarch Park

Quincy, MA  02269-9101

This  heater  is  designed  for  vent-free  op-

eration. State and local codes in some areas 

prohibit the use of vent-free heaters.

State of Massachusetts:

 The installation 

must  be  made  by  a  licensed  plumber  or 

gas  fitter  in  the  Commonwealth  of  Mas-

sachusetts.
Sellers  of  unvented  propane  or  natural 

gas-fired supplemental room heaters shall 

provide to each purchaser a copy of 527 

CMR 30 upon sale of the unit.
In  the  State  of  Massachusetts  the  gas 

cock must be a T-handle type. The State 

of  Massachusetts  requires  that  a  flexible 

appliance connector cannot exceed three 

feet in length.

PROCOM HEATING, INC. PATENT INFORMATION

This product may be covered by one or more of the following United States patents: 

8,915,239   8,851,065   8,764,436   8,757,202   8,757,139   8,752,541   8,568,136   

8,545,216   8,517,718   8,516,878   8,506,290   8,465,277   8,317,511   8,297,968   

8,281,781   8,241,034   8,235,708   8,152,515   8,011,920   7,967,006   7,967,007   

7,654,820   7,730,765   7,677,236   7,607,426   7,434,447

Summary of Contents for QNSD250T

Page 1: ...ot store or use gasoline or other flammable va pors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical...

Page 2: ...which it is installed Provisions for ad equatecombustionandventilationairmustbeprovided Refer to Air For Combustion and Ventilation section on page 7 of this manual WARNING Improper installation adjus...

Page 3: ...nce of alcohol and those at high altitudes NATURALAND PROPANE LP GAS Natural and Propane LP gas are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the o...

Page 4: ...prevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 12 Do not use this heater as a wood burning heater Use only the logs provided with the heater 13 Solid fuels...

Page 5: ...heater can easily be changed to Natural gas by having your quali fied installer follow the instructions on page 10 and the markings on the heater LOCAL CODES Install and use heater with care Follow al...

Page 6: ...air 2 If high humidity is experienced a dehu midifier may be used to help lower the water vapor content of the air 3 Do not use an unvented room heater as the primary heat source UNPACKING 1 Remove t...

Page 7: ...appli ances WARNING This heater shall not be installed in a room or space unless the required vol ume of indoor combustion air is provided by the method de scribed in the National Fuel Gas Code ANSI...

Page 8: ...to vinyl or cloth wall coverings or operating heater where impurities such as to baccosmoke aromaticcandles cleaning fluids oil or kerosene lamps etc in the air exist may cause walls to discolor Vent...

Page 9: ...ning wall Measure from outermost point of heater This heater is designed to sit directly on the floor or on a mantel base IMPORTANT You must maintain minimum wall and ceiling clearances during install...

Page 10: ...un m ximo de 14 W C Nunca conecte este producto directamente al tanque de suministro FOR NATURAL GAS SUPPLY PARA LA FUENTE DE GAS DEL NATURAL NOTICE An additional gas regulator will be necessary if t...

Page 11: ...the connection fitting While pushing in rotate the fitting clockwise until the threads engage the regulator After the fitting has been hand tightened into the regulator use a wrench to complete tight...

Page 12: ...n must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 10 page 13 IMPORTANT Install...

Page 13: ...from freezing rain or sleet For both gas types install sediment trap in supply line as shown in Figure 10 Place sediment trap where it is within reach for cleaning Place sediment trap where trapped m...

Page 14: ...or natural gas or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints If bubbles form there may be a leak 5 Correct all leaks at...

Page 15: ...t heater see Lighting Instructions on page 17 Check all other internal joints for leaks 7 Turn off heater see To Turn Off Gas Ap pliance page 18 AAA Battery Positive UP BATTERY INSTRUCTIONS CAUTION Do...

Page 16: ...side of log 1 with one end resting on log 3 IMPORTANT Make sure logs do not cover any burner ports It is very important to install the logs exactly as instructed Do not modify logs Use only logs suppl...

Page 17: ...th the screen in place Make sure screen is installed before running heater NOTICE Duringinitialoperationof new heater burning logs will give offapaper burningsmell Orange flame will also be present Op...

Page 18: ...nds release control knob 5 Make sure the heater screen is in place before operating heater TO TURN OFF GAS TO APPLIANCE MANUAL LIGHTING PROCEDURE Note If pilot does not stay lit refer to Troubleshooti...

Page 19: ...w in structions at bottom of this page Notice Do not mistake orange flames with yellow tipping Dirt or other fine particles enter the heater and burn causing brief patches of orange flame Approx 3 6 A...

Page 20: ...r Inlet Holes BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500 hours of operation or every three months We also recommend that you keep the burner tube...

Page 21: ...may blow through a drinking straw if compressed air is not available CARE AND MAINTENANCE ODS PILOT CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean Exterior Use a soft cloth...

Page 22: ...nlet pressure exceeds 9 WC This is to prevent the operation of the unit on the wrong gas propane LP If your natural gas supply exceeds 9 WC the unit will not operate Either contact your gas supplier t...

Page 23: ...ntrol knob while pressing ignitor button 3 Continue holding down con trol knob Repeat igniting op eration until air is removed 4 Clean ODS pilot see Care and Maintenance page 20 or replace ODS pilot a...

Page 24: ...Care and Maintenance page 20 2 Replace gas regulator 3 Contact local gas supplier Gas odor during com bustion 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at top...

Page 25: ...nd Maintenance page 20 Gas odor exists even when control knob is in OFF position 1 Gas leak See Warning Statement at top of page 22 2 Control valve is defective 1 Locate and correct all leaks see Chec...

Page 26: ...www usaprocom com 200198 01A 26 PARTS MODEL QNSD250T 7 8 6 1 2 3 4 12 13 11 15 14 5 9 10...

Page 27: ...ery 1 160960 01 Metal Regulator Cap 1 REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact...

Page 28: ...g condition Warranty part s MUST be obtained through ProCom Heating Inc who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty IMPORT...

Reviews: