4
The Dip Switches and Slide Switch are located in the bottom of the FP unit. Only the
settings when the power supply is turned on is effective to the Dip Switches and the Slide
Switch. After changing the settings of the Dip Switches and the Slide Switch, be sure to
restart your FP unit
SW1
• SW1-2 Dip Switch SW1-2 is used to display or hide the OSD.
To hide the OSD, set the switch to ON. To display the OSD, set the switch to OFF.
The default setting is OFF. (OSD is displayed.)
SW2
2
Dimensions
3
Dip Switches and Slide Switch
Switch
Setting
SW1-1 Reserved (Always OFF)
SW1-2 Display/Hide the OSD
SW1-3 Reserved (Always OFF)
SW1-4 Reserved (Always OFF
SW1-5 Reserved (Always OFF)
SW1-6 Reserved (Always OFF)
SW1-7 Reserved (Always OFF)
SW1-8 Reserved (Always OFF)
Switch
Setting
Slide Switch is used to switch the data input/output (command
control) method on the touch panel between USB and RS-232C
(Serial). The default setting is RS-232C.
301[11.85]
317[12.48]
243[9.57]
227[8.94]
58[2.28]
8[0.31]
Top View
Front View
Side View
Unit: mm [in]
Dip Switches(SW1)
Slide Switch(SW2)
Bottom View
ON
1
8
SW1
2
32
U
SB