Prism
Operation Manual Issue 2.00
Page 6.22
6.3.3.
Log Sequence (menu 3.3.)
The 'Log Sequence' sub-menu behaves exactly like the 'Run' sub-menu 3.1. (described
above) except that the progression of the Test Sequence is recorded in the DSA-1
Results Log.
A typical Test Sequence session might look something like this in the Results Log:
Prism Sound DSA-1 Results Log:
------------------------------
*** BLOCK 01 ***:
[Test Sequence:]
Strict Pro Test
1. Carrier qual PASSED
2. Pro CS PASSED
3. fs frequency PASSED
4. Amplitude PASSED
5. Jitter PASSED
6. Eye width PASSED
7. Channel Stat **FAILED CRC error
8. Biphase errs PASSED
*Tests Complete
If the Results Log is full, logging is prevented and this is reported by the message:
** LOG FULL
In this case, the log must be fully or partially cleared as described in section 6.8, which
contains a detailed description of the operation of the Results Log.
To return to the `Test Sequence' level of the menu system, press [EXIT].