516514
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
Figure 27
l. Disconnect wires from door switch. Refer to
NOTE: Refer to wiring diagram when rewiring
switch.
Figure 28
NOTE: Accumulator and hardware must be
removed prior to raising cabinet top to a vertical
position. Refer to Figure 10.
m. Remove two cabinet top hold-down screws.
Refer to Figure 28.
n. Lift cabinet top to a vertical position by hinging
it on the rear hold-down brackets. Refer to
Figure 29.
Figure 29
NOTE: While servicing, cabinet top may be raised
and hinged on the rear hold-down brackets or
supported against wall behind dryer.
o. Carefully withdraw the wire harness through
hole in cabinet top and lift the entire cabinet top
assembly off the rear hold-down brackets.
Refer to Figure 29.
p. Lay the cabinet top assembly flat, remove
carriage bolts, bracket, gasket and nuts holding
meter case to cabinet top and remove meter
case.
DOOR
SWITCH
TABS
D240SE3A
D395SE1A
CABINET TOP
HOLD-DOWN
SCREWS
REAR
HOLD-DOWN
BRACKETS
D253SE3A