70284701
9
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
Section 3
Troubleshooting
IMPORTANT: Refer to wiring diagram for aid in
testing tumbler components.
1. TUMBLER DOES NOT START
2. MOTOR DOES NOT START
POSSIBLE CAUSE
TO CORRECT
Inoperative motor relay.
• Test relay and replace if necessary.
Loading door is open.
• Close loading door completely.
Drying timer is in an off position. (Manual Timer
Models)
• Turn drying timer on.
Incorrect amount of coins inserted into coin drop.
• Check that proper amount of coins are inserted.
Inoperative coin drop.
• Test coin drop and replaced if inoperative.
PUSH-TO-START button not properly activated.
(Manual Timer Models)
• Press and hold in push-to-start button for three seconds.
Electrical power off or circuit breaker or fuse
blown.
• Check power supply, or replace fuses.
Lint panel open.
• Close and lock lint panel.
Blown fuse on tumbler.
• Check fuse (in junction box) and replace if necessary.
POSSIBLE CAUSE
TO CORRECT
Electrical power off or circuit breaker fuse blown.
• Check power supply, or replace fuses.
Loading door switch or lint panel switch not closed
or inoperative switch.
• Close door or test switch and replace if inoperative.
Door switch improperly adjusted.
• Refer to Adjustments Section for door switch adjustment.
Start circuit not complete.
• Press and hold in push-to-start button for three seconds.
Inoperative motor.
• Have motor tested and replace if inoperative.
Broken, loose, or incorrect wiring.
• Refer to wiring diagram.
Fan or fan motor binding.
• Replace fan or motor assembly.
Cylinder or cylinder motor binding.
• Replace cylinder, bearing, rollers, or motor assembly.
Inoperative transformer.
• Test and replace if necessary.
Inoperative motor relay.
• Test relay and replace if inoperative.
Inoperative airflow switch. (Only on manual timer
and rotary coin drop.)
• Test switch, replace or adjust as required.