24
70284701
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
28. CYLINDER BELT
Refer to Figure 13.
a. Unlock and remove lint panel.
b. Remove front panel.
c. Remove palnut, jamnut and washer from
trunnion shaft.
d. Remove drive belt service door at rear of
tumbler.
e. Raise motor assembly and run belt off motor
pulley.
f. Pull cylinder out through front of cabinet.
NOTE: Before reassembling cylinder, clean interior
of cabinet, checking to make sure all tools have been
removed.
Figure 13
TMB1847S
MOTOR
ASSEMBLY
IDLER
PULLEY
DRIVE
ACCESS
COVER
SPRING
CYLINDER
MOTOR
PULLEY
BELT
WASHER
Summary of Contents for D11