70284701
89
Section 7 Electronic Control Troubleshooting
WILL NOT HEAT – GAS – EDC MODELS
(Sheet 2 of 2)
T033D
Replace the stove
limit.
Is there voltage to the
output side of the stove
limit?
Correct wiring
between terminal
2 of ICM board
and stove limit.
Is there voltage to
terminal 2 of the ICM
board?
Replace ICM board.
Is there voltage at
terminal 1 of ICM
board?
Correct wiring
between gas valve
and ICM board.
Is there voltage across
the coils of the gas
valve?
Replace gas valve
coils or complete
gas valve.
Is there gas flow
through the gas valve?
Replace high
voltage ignition
cable or igniter.
Does the igniter spark?
Unit operational.
Is there a flame?
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
YES
NO
T033D
Summary of Contents for D11
Page 1: ...SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 12 03 70284701 D11 13 15 ...
Page 2: ......
Page 159: ......
Page 160: ......