Section 9 NetMaster Troubleshooting - Unit will not heat (Steam)
UNIT WILL NOT HEAT (STEAM)
(Sheet 2 of 2)
Please see following 2 pages for wiring diagram information.
Replace the stove
limit.
Is there voltage across
the stove limit?
Correct wiring
between steam
valve and stove
limit.
Is there voltage across
the coil of the steam valve?
NO
YES
NO
YES
(12)
(13)
Does the steam valve
open allowing steam to flow?
Unit operational.
Replace steam
valve.
No
TMB253S
No Heat
continued.