36
70284701
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
48. DRIVE BELT
Refer to Figure 26.
a. Unlock and remove lint panel. Refer to
Paragraph 20.
b. Remove front panel. Refer to Paragraph 16.
c. Remove palnut, jamnut and washer from
trunnion shaft. Refer to Figure 12.
d. Install cylinder guide tool on cylinder shaft.
Refer to Figure 14.
e. Remove drive access cover at rear of tumbler.
Refer to Figure 22.
f. Raise motor assembly and run belt off motor
pulley.
g. Pull cylinder out through front of cabinet. Refer
to Paragraph 27.
NOTE: Before reassembling cylinder, clean interior
of cabinet, checking to make sure all tools have been
removed.
Figure 26
TMB1847S
MOTOR
ASSEMBLY
IDLER
PULLEY
DRIVE
ACCESS
COVER
SPRING
CYLINDER
MOTOR
PULLEY
BELT
WASHER
Summary of Contents for D11
Page 1: ...SERVICE MANUAL INDUSTRIAL DRYERS PUBLICATION DATE 12 03 70284701 D11 13 15 ...
Page 2: ......
Page 159: ......
Page 160: ......