background image

 

4

MULTI-FUNCTION
INDICATOR (RED,
GREEN, AMBER)

POWER
INDICATOR
(GREEN)

 

Apply Power 

 
When power is applied, the green LED indicator is continuously ON. 
 
When initially powered up, the DS71/DS72 controller displays the firmware version 
number by flashing the 

multi-function/multi-color

 LED indicator, first 

red 

then 

green 

(See FIRMWARE VERSION later in this document on page 8).  When troubleshooting 
with Prime Controls, it is helpful to know the version number.  The controller then 
checks for a valid probe.  If a fault is detected, it could be one of the following problems: 
a) the probe is not connected; b) there is an open connection in the cable to the probe; 
c) weak or no magnetic signal present.  The multi-function indicator will flash red at a 
rate of 10Hz until the fault is cleared.  If no fault is detected the controller goes into 
normal the sensing operation.  Normal indicator colors are covered on page 8.  If the 
magnetic field signal is strong the multi-function indicator will be off. (this assumes the 
probe face was mounted within 50mm of the magnetic conveyor.) 

 
 
PUSHBUTTON OPERATION

 

 
The small pushbutton mounts flush with the 
face of the unit to insure no inadvertent 
bumping can cause a calibration mistake.  
In addition to calibration, the pushbutton is 
used to control two other operational modes.  
 
They modes are:   
 

1.  During operation, pressing and holding the pushbutton for three seconds more, 

initiates meter mode. 

2.  From meter mode, pressing the pushbutton once exits meter mode. 
 

3.  From error mode, pressing the pushbutton once retries calibration. 

 

4.  From calibration mode, pressing and releasing once within 3 seconds, initiates 

calibration on a single thickness of metal. 

5.  From calibration mode, pressing the pushbutton twice within 1.0 second, initiates 

two-sample calibration mode and records the first point.  A third tap records the 
second calibration point, installs the new calibration and exits calibration mode. 

 

Summary of Contents for FLUXIMITY DS71

Page 1: ...ers are explained is this instruction sheet The Fluximity system includes a microcontroller based control module in a 18mm threaded aluminum housing The Controller is connected to a family of magnetic...

Page 2: ...ule Installation The DS71 72 Controller module is designed to mount with a simple bracket where convenient between the probe and a higher level controller such as a PLC Avoid mounting locations with e...

Page 3: ...t a location where the maximum field is not blocked may cause false doubles During production the metal may move to a point where more flux is covered This is especially true when the shape of the bla...

Page 4: ...rmal indicator colors are covered on page 8 If the magnetic field signal is strong the multi function indicator will be off this assumes the probe face was mounted within 50mm of the magnetic conveyor...

Page 5: ...ignal The Fluximity operates best if the magnetic strength is 100 gauss Gauss G is a unit of measurement for magnetic field strength or flux density For example approx 1 gauss from earth s magnetic no...

Page 6: ...econds elapses with no press of the pushbutton The detector has a standby calibration feature that permits calibration while the metal is moving Press the pushbutton once with no metal between the mag...

Page 7: ...thickness of the two samples is too close for reliable gauging the indicator flashes amber at a 10 Hz rate for up to 15 seconds or until the pushbutton is pressed again After 15 seconds it returns to...

Page 8: ...ber and then begins flashing red rapidly 10 Hz This can indicate a there is metal present b the probe is disconnected or c the cable to the probe has an open or d the probe is faulty During Single Hit...

Page 9: ...FIRMWARE VERSION The format of the firmware version number is of the form 1 2 comprising a single digit integer part and a single digit fractional part When first powered up the controller displays t...

Page 10: ...ection 12 mm Connector Pin 4 Max source current 50mA fuse limited Output Voltage High Supply Voltage less 1 volt Over current protection Self resetting thermal fuse ESD protection Transient Voltage Su...

Page 11: ...11 DS71 DRIVE CIRCUITRY CONTROLLER 30V 30V 30V 2 1 4 3 50 mA 50 mA V COM SINGLE NO DOUBLE DS72 DRIVE CIRCUITRY CONTROLLER 30V 30V 30V 2 1 4 3 50 mA 50 mA V COM SINGLE NO DOUBLE...

Page 12: ...F ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE THE LIABILITY OF PRIME CONTROLS TO ANY PURCHASER SHAL...

Reviews: