Page 27
b) Entity parameters and connections of output or generation
b.1)
Voltage (V) Output:
U
i
= 30 V
U
o
= 17.1 V
I
i
= 100 mA
I
o
= 22.3 mA
P
i
= 750 mW
P
o
= 76.5 mW
C
i
= 0 nF
C
o
= 33 nF
L
i
= 400 µH
L
o
= 1.18 mH
CAUTION:
Always connect the terminal V OUT to the
positive and the terminal V GND to the negative
in order to not invalidate the protection mode.
Fig. 09
– V Output
b.2)
Current (mA) output active mode:
U
o
= 18.2 V
I
o
= 49 mA
P
o
= 207 mW
C
o
= 85 nF
L
o
= 6.7 mH
Fig. 10
– mA Output active mode