45
5.
Click
Save
.
Configuring Alarm Output
After alarm output is triggered by a motion detection alarm, temperature alarm or Boolean alarm, the camera can
output alarm information to the third-party device if alarm output is set correctly to Normally Open or Normally
Closed. The alarm output duration is configurable.
1.
Click
Setup
>
Events
>
Alarm Output
.
2.
Select the alarm and set the alarm name. Set the
status to
Normally Open
(default setting) and set
the alarm duration.
3.
Click
Save
.
CAUTION:
Strictly follow the sequence when powering on the devices to avoid damaging camera components:
Check that the alarm type is set to Normally Open (default setting), and that the camera and the alarm output
device are powered off.
After completing the connection, power on the alarm output device first and then power on the camera.
Configuring Capture
With the function of capture configured, when an alarm is triggered, the camera will automatically upload the
captured snapshots to the FTP server or send snapshots the specified email address.
1.
Click
Setup
>
Events
>
Capture
.
2.
Enable
Capture
, and configure relevant
parameters.
3.
Click
Save
.