Inverse Multiplexer (IMUX) Card Settings
CURRENT PROFILE
The Current Profile indicates if a call profile is loaded into this HSU port’s dialing memory.
The options for this parameter are none (indicating that the copy of a call profile template has
not been downloaded to this port) or loaded (indicating that the copy of a call profile template
has been downloaded to this port).
Table 7-6. HSU Dial Screen of Actions
7.2.5
HSU Call Profile Screen
Once a call profile is copied from the Interface card templates, it can be used by the DTE on
HSU ports for placing calls to other devices throughout the ISDN network. The HSU Call
Profile screen is shown as Figure 7-5. Table 7-7 lists the settings and defaults for each
parameter.
Once the appropriate information is inserted or changed on the fields of this screen, you can
place a call by pressing the "D" (Dial) command from the Menu of Actions. When finished,
the call can be disconnected by pressing the "H" (Hang-up) command from the Menu of
Actions.
It is important to note that the HSU port used to dial the call must by in the standby state
when the call is placed. The state changes from standby to active after the call has been
placed. The system will not allow a call to be placed from an active port.
Note:
Any changes made to the loaded call profile will stay with the call profile copy until
changed in a future session. Changes made to this copy will not change the call profile
template on the Interface card.
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Updates certain time-related information fields that are not automatically
updated (i.e. performance and test data).
proFile
Brings up the call profile screen.
Load
This option loads a profile from the Interface card template. A call profile
number must be inserted. Changes the Current Profile parameter from "none"
to "loaded."
Main
Returns to the HSU card main screen. If changes are made to settings and not
saved, you will be prompted to save or lose changes.
Summary of Contents for 600
Page 1: ...Server Cards Reference Guide Release 5 3 1 September 2000 ...
Page 4: ...Model No Running Head ...
Page 10: ...vi Server Cards Model No Running Head Contents ...
Page 14: ...x Server Cards Model No Running Head Figures ...
Page 56: ...2 32 Server Cards Model No Running Head ACS FRS Server Card Specifications FRS Card ...
Page 74: ...3 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card ...
Page 110: ...4 36 Server Cards Model No Running Head ATM Server Card Specifications ATM Card ...
Page 150: ...5 40 Server Cards Model No Running Head ISDN PRI Card Troubleshooting ISDN PRI Card ...
Page 208: ...7 18 Server Cards Model No Running Head IMUX Card Troubleshooting IMUX Card ...