3-10
Server Cards
Model No.
Running Head
ACS-MCC Card User Screens and Settings
MCC Card
NETMASK
The NETMASK setting together with the IP ADDR identifies the network for this port.
FORMAT
The Format setting determines the format of the information received from the remote system
unit. For the numbered ports (1-128), the options are b7r (for T1 links) and b4r (for E1 links).
For ports C1-C3, the options are hdlc (high-level data link control) and fr (frame relay). If fr
is selected, the user must select a DLCI (data link connection identifier), which corresponds
to the virtual circuit number of the frame relay destination address. When more than one TS
is selected, the MTU is 1,500. The internal MTU is expanded by four on the WAN segment to
allow 1,500 byte frames to pass with the addition of the frame relay header without
fragmentation. When fr is selected, more than one TS must be allocated.
RIP
When the Routing Information Protocol (RIP) setting is off (default), no RIP traffic is allowed
into or out of the Ethernet interface. Setting this variable to rx allows incoming RIP traffic
only, while setting it to tx allows only outgoing RIP traffic. Setting this variable to rx/tx allows
both incoming and outgoing RIP traffic.
Note:
Due to the high number of interfaces on the ACS-MCC card and the relatively low
bandwidth of the Munich interfaces, the user should be cautious about implementing
the RIP option, as there is a substantial risk of broadcast storms causing congestion
in the network.
SH
When the Split Horizon (SH) variable is set to on, the ACS-MCC card does not automatically
send RIP information along routes it "learned" through the same interface. The default is off.
WEIGHT
The Weight parameter assigns a weighting variable to the specified interface. The number
must be between 1 and 15. The default is 1.
Summary of Contents for 600
Page 1: ...Server Cards Reference Guide Release 5 3 1 September 2000 ...
Page 4: ...Model No Running Head ...
Page 10: ...vi Server Cards Model No Running Head Contents ...
Page 14: ...x Server Cards Model No Running Head Figures ...
Page 56: ...2 32 Server Cards Model No Running Head ACS FRS Server Card Specifications FRS Card ...
Page 74: ...3 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card ...
Page 110: ...4 36 Server Cards Model No Running Head ATM Server Card Specifications ATM Card ...
Page 150: ...5 40 Server Cards Model No Running Head ISDN PRI Card Troubleshooting ISDN PRI Card ...
Page 208: ...7 18 Server Cards Model No Running Head IMUX Card Troubleshooting IMUX Card ...