4-4
Server Cards
Model No.
Running Head
ACS-ATM Card User Screens and Settings
ATM Card
Table 4-1. ACS-ATM Card Main Screen Actions (DS3)
Table 4-2. ACS-ATM Card Main Screen Options and Defaults (DS3)
STATE (DS3)
The State setting determines whether the port is active or inactive. Set State to stdby (standby)
for ports not being used or not yet configured. Set it to actv (active) for ports that are ready
for use for ATM traffic.
FORMAT (DS3)
The Format setting indicates the variety of DS3 C-bit application used by this port. The
choices are Cbit and M23. This parameter is defined in RFC 1407.
CELL FRM (DS3)
The Cell Framing setting indicates the way ATM cells are constructed from the DS3 bitstream.
The two options are plcp (cells are constructed from the PLCP mapping bits) and hcs (the cells
are constructed from the HEC in the cell header).
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Redraws the screen.
uNi
Brings up the User Network Interface (UNI) Configuration Screen.
Vbr
Brings up the Variable Bit Rate (VBR) Configuration Screen.
Cbr
Brings up the Constant Bit Rate (CBR) Configuration Screen.
Perf
Brings up the DS3 Port Performance Data Screen.
Main
Returns to the System Main Screen. If changes are made to settings and not
saved, you will be prompted to save or lose changes.
Parameter
User Options
Default
STATE
stdby actv
stdby
FORMAT
Cbit M23
Cbit
CELL FRM
plcp hcs
plcp
LB CFG
off local line payld cell
off
LB GEN
off line paylod reset
off
LB DET
off on w/to
off
TX CLKSRC
line plcp
line
TX-RX SCRAM
yes no
yes
TX-LBO
off on
off
IDLE-UASN
uasn idle
uasn
Summary of Contents for 600
Page 1: ...Server Cards Reference Guide Release 5 3 1 September 2000 ...
Page 4: ...Model No Running Head ...
Page 10: ...vi Server Cards Model No Running Head Contents ...
Page 14: ...x Server Cards Model No Running Head Figures ...
Page 56: ...2 32 Server Cards Model No Running Head ACS FRS Server Card Specifications FRS Card ...
Page 74: ...3 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card ...
Page 110: ...4 36 Server Cards Model No Running Head ATM Server Card Specifications ATM Card ...
Page 150: ...5 40 Server Cards Model No Running Head ISDN PRI Card Troubleshooting ISDN PRI Card ...
Page 208: ...7 18 Server Cards Model No Running Head IMUX Card Troubleshooting IMUX Card ...