Server Cards
6-31
ACS-PRI/BRI Card
Configuring ISDN Features
Another example of this procedure is shown in Figure 6-18. If you want a single incoming
trunk group to be routed to only one outgoing trunk group, D channel #1, trunk group “A” is
routed to D channel #2, trunk group “B.” The alternate routes 2-3 must contain the same
information in alternate route #2. Since this is the only alternative route, if that route is busy,
the unit will drop the call.
Figure 6-18. Add Trunk Route Screen
6.4.8
Assignment of Services
Some carriers support call-by-call service selection in their ACS-PRI/BRI offerings. This
feature allows users to select a different service (and, usually, a different billing rate) for each
call placed.
If call-by-call service is supported, users must tell the system which service(s) is/are supported
by each D channel, and what the code is for each service. The carrier will supply a service code
for each supported service. The Service format code is always two digits, a space and the
name of the service. When placing a call using call profiles, only valid service codes will be
allowed (see Call Profiles below for additional information about services).
If call-by-call service selection is not supported by the carrier or not required for the user’s
applications, then there is no need to assign service to a D channel.
dchan:1 trunk:A
dchan:2
trunk:B
dchan:3
trunk:C
dchan:4
trunk:D
dchan:1 trunk:A
dchan:2
trunk:B
dchan:2
trunk:B
dchan:1
trunk:B
Add | uPdate | dElete | pgUp | pgDn | Main
Summary of Contents for 600
Page 1: ...Server Cards Reference Guide Release 5 3 1 September 2000 ...
Page 4: ...Model No Running Head ...
Page 10: ...vi Server Cards Model No Running Head Contents ...
Page 14: ...x Server Cards Model No Running Head Figures ...
Page 56: ...2 32 Server Cards Model No Running Head ACS FRS Server Card Specifications FRS Card ...
Page 74: ...3 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card ...
Page 110: ...4 36 Server Cards Model No Running Head ATM Server Card Specifications ATM Card ...
Page 150: ...5 40 Server Cards Model No Running Head ISDN PRI Card Troubleshooting ISDN PRI Card ...
Page 208: ...7 18 Server Cards Model No Running Head IMUX Card Troubleshooting IMUX Card ...