2-6
Server Cards
Model No.
Running Head
ACS-FRS Card User Screens and Settings
FRS Card
STATE
The State setting determines whether the port is active or inactive. Set the State field to stdby
(standby) for ports you are not using or have not yet configured. Or, set it to actv (active) for
ports that are ready for use.
WAN/SRV
The WAN setting identifies the WAN link assigned to this port. You do not have to assign all
ports on the same card to the same WAN link. You also don’t have to assign card ports to
contiguous time slots of a WAN link. The default value is none.
TS
The Time Slot setting identifies the time slots on the WAN link when wan is selected in the
previous setting. The ACS-FRS card can use many (up to 24 T1 or 31 E1) time slots on a
single WAN port, in order to create a super-rate circuit for an individual FRS port. One or all
time slots of a T1 or E1 link can be assembled for use by the FRS port, according to the speed
requirements of the DTE.
You can assign time slots by pressing <Enter> and using the space bar to select and deselect
the required number of time slots. These assignments do not have to be contiguous.
RATE
The Rate setting allows you to adjust the speed of the circuit according to the application
requirements. The only speed available for ports C1to C4 is 64k (64 kbps). However, ports 1
to 64 can be set to either 56k or 64k.
PORT TYPE
The Port Type identifies the type of interface expected for this port. The selections are none,
u-dce (User-to Network Interface), nni (Network to Network Interface), u-dte (User-to
Terminal Equipment), and frad (Frame Relay Assembler/Dissembler).
LMI
The Local Management Interface setting allows you to select the protocol to be used by this
port. The options are none, ansi (ANSI T1.617 Annex D), ccitt (ITU Q.933 Annex A), and
lmi (Group of Four specification).
Summary of Contents for 600
Page 1: ...Server Cards Reference Guide Release 5 3 1 September 2000 ...
Page 4: ...Model No Running Head ...
Page 10: ...vi Server Cards Model No Running Head Contents ...
Page 14: ...x Server Cards Model No Running Head Figures ...
Page 56: ...2 32 Server Cards Model No Running Head ACS FRS Server Card Specifications FRS Card ...
Page 74: ...3 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card ...
Page 110: ...4 36 Server Cards Model No Running Head ATM Server Card Specifications ATM Card ...
Page 150: ...5 40 Server Cards Model No Running Head ISDN PRI Card Troubleshooting ISDN PRI Card ...
Page 208: ...7 18 Server Cards Model No Running Head IMUX Card Troubleshooting IMUX Card ...