5.17 Elliptical Fitness Crosstrainer
Page 67
Procedure 6.23 - Replacing the Ramp Assembly
Procedure
1.
Set the on/off switch in the “off” position and disconnect the power adapter from the EFX.
2.
Remove the rear cover per Procedure 6.1 and pivot both stairarms to the rear of the unit.
1.
Remove the six screws that retain the front half front cover to the rear half of the front cover
and remove the front half cover.
2.
Remove the retaining clip from each lift nut mounting pin. Support the lift ramp assembly
and remove the lift mounting pins from the lift nut. Raise the ramp and support it from the
handlebars using a bungi cord (See Diagram 4.1). Do not allow the lift motor nut to rotate. If
the lift motor nut is allowed to rotate, the lift must be re-calibrated per Procedure 5.2.
3.
Remove the nuts and bolts that fasten the lower ends of the ramp to the frame (See
Diagram 6.21).
Diagram 6.21 - Ramp Mounting
4.
Support the ramp and remove the bungi cord, lift the ramp off of the frame.
5.
Set the replacement ramp at it’s mounting position and support it from the handlebars with a
bungi cord.
6.
Replace and tighten the ramp mounting bolts removed in step 3. Do not overtighten the
ramp mounting bolts, the ramp must pivot freely.
Ramp
Mounting Bolt