5.17 Ellipitical Fitness Crosstrainer
Page 38
Procedure 6.6 - Replacing the Input Power Jack
Removing the Power Entry Module
1.
Set the on/off switch in the “off” position and disconnect the power adapter from the EFX.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One, Things You Should Know.
2.
Remove the rear covers per Procedure 6.1.
3.
Remove the mounting nut from the input power jack.
Diagram 6.6 - Input Power Jack
4.
Remove the input power jack from the input panel.
5.
Disconnect both red wires from on/off switch and the red and black wires from the capacitor.
Disconnect the red wire from J4 of the lower PCA and the black wire from J5 of the lower
PCA. Remove and discard the input power jack and the associated wiring.
6.
Set the replacement input power jack at it’s mounting and secure it with the furnished nut.
7.
Reconnect the wiring removed in step 5. The red wires at the on/off switch can be replaced
in any order. At the capacitor, the black wire must connect to the (-) negative terminal and
the red wire must connect to the (+) positive terminal. At the lower PCA the black wire must
connect to J5 and the red wire must connect to J4. Verify that the wiring is connected
correctly before applying power to the EFX.
Input Power Jack