Model PD655 Large Display Process Meter
Instruction Manual
58
Press
ENTER,
then press
ENTER
again when the
set points (
SetPtS
) function appears.
SEtPtS
Preset values for set points assigned to
total with offset
If a set point was assigned to total with offset
during the
Setup
function, it means that this
set point and the one before it function as a
pair. That is, the first relay will always trip a
specified number of counts before the second
relay. This is called the preset offset value
and it is programmed as the first “preset” in a
pair of set points setup for offset. The second
value in a pair of set points setup for offset
represents the actual preset value.
Meter displaying preset offset
between set points 1 and 2
Meter displaying preset for set
point 2
Preset value (# LED on left is
steady-on)
Set the display for preset offset and preset values
The entire display will flash for three seconds. For
instructions see
Five Basic Digit/Display Setting
Instructions,
page 30.
070.00
then
170.00
then
120.00
final
125.00